Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system.


ABSTRACT: Cardiovascular Magnetic Resonance (CMR) myocardial perfusion imaging has the potential to evolve into a method allowing full quantification of myocardial blood flow (MBF) in clinical routine. Multiple quantification pathways have been proposed. However at present it remains unclear which algorithm is the most accurate. An isolated perfused, magnetic resonance (MR) compatible pig heart model allows very accurate titration of MBF and in combination with high-resolution assessment of fluorescently-labeled microspheres represents a near optimal platform for validation. We sought to investigate which algorithm is most suited to quantify myocardial perfusion by CMR at 1.5 and 3 Tesla using state of the art CMR perfusion techniques and quantification algorithms.First-pass perfusion CMR was performed in an MR compatible blood perfused pig heart model. We acquired perfusion images at physiological flow ("rest"), reduced flow ("ischaemia") and during adenosine-induced hyperaemia ("hyperaemia") as well as during coronary occlusion. Perfusion CMR was performed at 1.5 Tesla (n?=?4 animals) and at 3 Tesla (n?=?4 animals). Fluorescently-labeled microspheres and externally controlled coronary blood flow served as reference standards for comparison of different quantification strategies, namely Fermi function deconvolution (Fermi), autoregressive moving average modelling (ARMA), exponential basis deconvolution (Exponential) and B-spline basis deconvolution (B-spline).All CMR derived MBF estimates significantly correlated with microsphere results. The best correlation was achieved with Fermi function deconvolution both at 1.5 Tesla (r?=?0.93, p?

SUBMITTER: Schuster A 

PROVIDER: S-EPMC4195947 | biostudies-literature | 2014 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system.

Schuster Andreas A   Zarinabad Niloufar N   Ishida Masaki M   Sinclair Matthew M   van den Wijngaard Jeroen Phm JP   Morton Geraint G   Hautvast Gilion Ltf GL   Bigalke Boris B   van Horssen Pepijn P   Smith Nicolas N   Spaan Jos Ae JA   Siebes Maria M   Chiribiri Amedeo A   Nagel Eike E  

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance 20141014


<h4>Background</h4>Cardiovascular Magnetic Resonance (CMR) myocardial perfusion imaging has the potential to evolve into a method allowing full quantification of myocardial blood flow (MBF) in clinical routine. Multiple quantification pathways have been proposed. However at present it remains unclear which algorithm is the most accurate. An isolated perfused, magnetic resonance (MR) compatible pig heart model allows very accurate titration of MBF and in combination with high-resolution assessmen  ...[more]

Similar Datasets

| S-EPMC4570548 | biostudies-literature
| S-EPMC2964700 | biostudies-literature
| S-EPMC3744172 | biostudies-literature
| S-EPMC3552720 | biostudies-literature
| S-EPMC2720808 | biostudies-literature
| S-EPMC7392760 | biostudies-literature
| S-EPMC5722766 | biostudies-literature
| S-EPMC7611223 | biostudies-literature
| S-EPMC3403962 | biostudies-literature
| S-EPMC4731584 | biostudies-literature