Unknown

Dataset Information

0

Loop-mediated isothermal amplification assays for screening of bacterial integrons.


ABSTRACT: BACKGROUND: The occurrence and prevalence of integrons in clinical microorganisms and their role played in antimicrobial resistance have been well studied recently. As screening and detection of integrons are concerned, current diagnostic methodologies are restricted by significant drawbacks and novel methods are required for integrons detection. RESULTS: In this study, three loop-mediated isothermal amplification (LAMP) assays targeting on class 1, 2 and 3 integrons were implemented and evaluated. Optimization of these detection assays were performed, including studing on the reaction temperature, volume, time, sensitivity and specificity (both primers and targets). Application of the established LAMP assays were further verified on a total of 1082 isolates (previously identified to be 397 integron-positive and 685 integron-negative strains). According to the results, the indispensability of each primer had been confirmed and the optimal reaction temperature, volume and time were found to be 65°C, 45 min and 25 ?L, respectively. As application was concerned, 361, 28 and 8 isolates carrying intI1, intI2 and intI3 yielded positive amplicons, respectively. Other 685 integron-negative bacteria were negative for the integron-screening LAMP assays, totaling the detection rate and specificity to be 100%. CONCLUSIONS: The intI1-, intI2- and intI3-LAMP assays established in this study were demonstrated to be the valid and rapid detection methodologies for the screening of bacterial integrons.

SUBMITTER: Yu G 

PROVIDER: S-EPMC4222780 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Loop-mediated isothermal amplification assays for screening of bacterial integrons.

Yu Guangchao G   Chen Lei L   Lin Chii-wann CW   Li Bing B   Cui Hemiao H   Chen Siyi S   Miao Jian J   Bian Huawei H   Chen Dingqiang D   Deng Yang Y  

Biological research 20141002


<h4>Background</h4>The occurrence and prevalence of integrons in clinical microorganisms and their role played in antimicrobial resistance have been well studied recently. As screening and detection of integrons are concerned, current diagnostic methodologies are restricted by significant drawbacks and novel methods are required for integrons detection.<h4>Results</h4>In this study, three loop-mediated isothermal amplification (LAMP) assays targeting on class 1, 2 and 3 integrons were implemente  ...[more]

Similar Datasets

| S-EPMC7182526 | biostudies-literature
| S-EPMC4139188 | biostudies-other
| S-EPMC102748 | biostudies-literature
| S-EPMC3000401 | biostudies-literature
| S-EPMC7166982 | biostudies-literature
| S-EPMC8543070 | biostudies-literature
| S-EPMC4417551 | biostudies-literature
| S-EPMC10722318 | biostudies-literature
| S-EPMC3217895 | biostudies-literature
| S-EPMC8595270 | biostudies-literature