Unknown

Dataset Information

0

Mapping of autogenous saphenous veins as an imaging adjunct to peripheral MR angiography in patients with peripheral arterial occlusive disease and peripheral bypass grafting: prospective comparison with ultrasound and intraoperative findings.


ABSTRACT:

Background

Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery.

Methods

38 patients with peripheral arterial occlusive disease (21 men; mean age: 71 years, range, 44-88 years) underwent peripheral MR angiography using the blood pool contrast agent Gadofosveset trisodium. Apart from primary arterial assessment images were evaluated in order to determine great saphenous vein diameters at three levels: below the saphenofemoral junction, mid thigh and 10 cm above the knee joint (usability: diameter range: >3 and <10 mm at one level and >3.5 and <10 mm at a neighboring level). Duplex ultrasound was performed by an independent examiner providing diameter measurements at the same levels. Additionally, vessel usability was determined intraoperatively by the vascular surgeon during subsequent bypass surgery.

Results

Mean venous diameters for MR angiography/duplex ultrasound were 5.4±2.6/5.5±2.8 mm (level 1), 4.7±2.7/4.6±2.9 mm (level 2) and 4.4±2.2/4.5±2.3 mm (level 3), respectively, without significant differences between the modalities (P?=?0.207/0.806/0.518). Subsequent surgery was performed in 27/38 patients. A suitable saphenous vein was diagnosed in 25 and non-usability was diagnosed in 2 of the 27 patients based on MR angiography/duplex ultrasound, respectively. Usability was confirmed by intraoperative assessment in all of the 24 patients that received a venous bypass graft in subsequent bypass surgery. In 1 case, in which the great saphenous vein was assessed as useable by both MR angiography and duplex ultrasound, it was not used during subsequent bypass surgery due to the patients clinical condition and comorbidities.

Conclusion

Simultaneous mapping of the great saphenous vein as an imaging adjunct to peripheral MR angiography with a blood pool contrast agent is an alternative to additive duplex ultrasound in patients undergoing subsequent peripheral bypass grafting.

SUBMITTER: Jah-Kabba AM 

PROVIDER: S-EPMC4236072 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Mapping of autogenous saphenous veins as an imaging adjunct to peripheral MR angiography in patients with peripheral arterial occlusive disease and peripheral bypass grafting: prospective comparison with ultrasound and intraoperative findings.

Jah-Kabba Ann-Marie Bintu Munda AM   Kukuk Guido Matthias GM   Hadizadeh Dariusch Reza DR   Träber Frank F   Koscielny Arne A   Kabba Mustapha Sundifu MS   Verrel Frauke F   Schild Hans Heinz HH   Willinek Winfried Albert WA  

PloS one 20141118 11


<h4>Background</h4>Mapping of the great saphenous vein is very important for planning of peripheral and coronary bypass surgery. This study investigated mapping of the great saphenous vein as an adjunct to peripheral MR angiography using a blood pool contrast agent in patients who were referred for evaluation of peripheral arterial occlusive disease and bypass surgery.<h4>Methods</h4>38 patients with peripheral arterial occlusive disease (21 men; mean age: 71 years, range, 44-88 years) underwent  ...[more]

Similar Datasets

| S-EPMC4102634 | biostudies-literature
| S-EPMC1762105 | biostudies-other
2013-10-01 | GSE51260 | GEO
| S-EPMC3908920 | biostudies-literature
2013-10-01 | E-GEOD-51260 | biostudies-arrayexpress
| S-EPMC8118858 | biostudies-literature
| S-EPMC9454806 | biostudies-literature
| S-EPMC2817830 | biostudies-literature
| S-EPMC3121010 | biostudies-other
2008-06-15 | E-GEOD-7190 | biostudies-arrayexpress