Unknown

Dataset Information

0

Comparison of select analytes in exhaled aerosol from e-cigarettes with exhaled smoke from a conventional cigarette and exhaled breaths.


ABSTRACT: Exhaled aerosols were collected following the use of two leading U.S. commercial electronic cigarettes (e-cigarettes) and a conventional cigarette by human subjects and analyzed for phenolics, carbonyls, water, glycerin and nicotine using a vacuum-assisted filter pad capture system. Exhaled breath blanks were determined for each subject prior to each product use and aerosol collection session. Distribution and mass balance of exhaled e-cigarette aerosol composition was greater than 99.9% water and glycerin, and a small amount (<0.06%) of nicotine. Total phenolic content in exhaled e-cigarette aerosol was not distinguishable from exhaled breath blanks, while total phenolics in exhaled cigarette smoke were significantly greater than in exhaled e-cigarette aerosol and exhaled breaths, averaging 66 µg/session (range 36 to 117 µg/session). The total carbonyls in exhaled e-cigarette aerosols were also not distinguishable from exhaled breaths or room air blanks. Total carbonyls in exhaled cigarette smoke was significantly greater than in exhaled e-cigarette aerosols, exhaled breath and room air blanks, averaging 242 µg/session (range 136 to 352 µg/session). These results indicate that exhaled e-cigarette aerosol does not increase bystander exposure for phenolics and carbonyls above the levels observed in exhaled breaths of air.

SUBMITTER: Long GA 

PROVIDER: S-EPMC4245607 | biostudies-literature | 2014 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of select analytes in exhaled aerosol from e-cigarettes with exhaled smoke from a conventional cigarette and exhaled breaths.

Long Gerald A GA  

International journal of environmental research and public health 20141027 11


Exhaled aerosols were collected following the use of two leading U.S. commercial electronic cigarettes (e-cigarettes) and a conventional cigarette by human subjects and analyzed for phenolics, carbonyls, water, glycerin and nicotine using a vacuum-assisted filter pad capture system. Exhaled breath blanks were determined for each subject prior to each product use and aerosol collection session. Distribution and mass balance of exhaled e-cigarette aerosol composition was greater than 99.9% water a  ...[more]

Similar Datasets

| S-EPMC6949915 | biostudies-literature
| S-EPMC6584902 | biostudies-literature
| S-EPMC6664429 | biostudies-literature
| S-EPMC7068890 | biostudies-literature
| S-EPMC2955215 | biostudies-literature
| S-EPMC7885788 | biostudies-literature
| S-EPMC6751519 | biostudies-literature
| S-EPMC6410739 | biostudies-literature
| S-EPMC4142115 | biostudies-literature
| S-EPMC4907307 | biostudies-literature