Unknown

Dataset Information

0

Decreased variability of the 6-minute walk test by heart rate correction in patients with neuromuscular disease.


ABSTRACT:

Objective

The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction.

Methods

Sixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dystrophia Myotonica and Congenital Myopathy and 12 healthy subjects were studied. Patients were excluded if they had cardiac arrhythmias, if they received drug treatment for hypertension or any other medical conditions that could interfere with the interpretation of the heart rate and walking capability. All completed three 6-minute walk tests on three different test-days. Heart rate was measured continuously.

Results

Successive standard 6-minute walk tests showed considerable learning effects between Tests 1 and 2 (4.9%; P = 0.026), and Tests 2 and 3 (4.5%; P = 0.020) in patients. The same was seen in controls between Tests 1 and 2 (8.1%; P = 0.039)). Heart rate correction abolished this learning effect.

Conclusion

A modified 6-minute walk test, by correcting walking distance with average heart rate during walking, decreases the variability among repeated 6-minute walk tests, and should be considered as an alternative outcome measure to the standard 6-minute walk test in future clinical follow-up and treatment trials.

SUBMITTER: Prahm KP 

PROVIDER: S-EPMC4257612 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Decreased variability of the 6-minute walk test by heart rate correction in patients with neuromuscular disease.

Prahm Kira P KP   Witting Nanna N   Vissing John J  

PloS one 20141205 12


<h4>Objective</h4>The 6-minute walk test is widely used to assess functional status in neurological disorders. However, the test is subject to great inter-test variability due to fluctuating motivation, fatigue and learning effects. We investigated whether inter-test variability of the 6MWT can be reduced by heart rate correction.<h4>Methods</h4>Sixteen patients with neuromuscular diseases, including Facioscapulohumeral muscular dystrophy, Limb-girdle muscular dystrophy, Charcot-Marie-Tooths, Dy  ...[more]

Similar Datasets

| S-EPMC6423958 | biostudies-literature
| S-EPMC4485950 | biostudies-literature
| S-EPMC9713139 | biostudies-literature
| S-EPMC8795411 | biostudies-literature
| S-EPMC5147870 | biostudies-literature
| S-EPMC9702990 | biostudies-literature
| S-EPMC6328920 | biostudies-literature
| S-EPMC4183675 | biostudies-literature
| S-EPMC4913584 | biostudies-literature