Understanding the relationship between biotherapeutic protein stability and solid-liquid interfacial shear in constant region mutants of IgG1 and IgG4.


ABSTRACT: Relative stability of therapeutic antibody candidates is currently evaluated primarily through their response to thermal degradation, yet this technique is not always predictive of stability in manufacture, shipping, and storage. A rotating disk shear device is proposed that produces defined shear conditions at a known solid-liquid interface to measure stability in this environment. Five variants of IgG1 and IgG4 antibodies were created using combinations of two discrete triple amino acid sequence mutations denoted TM and YTE. Antibodies were ranked for stability based on shear device output (protein decay coefficient, PDC), and compared with accelerated thermal stability data and the melting temperature of the CH2 domain (Tm 1) from differential scanning calorimetry to investigate technique complimentarity. Results suggest that the techniques are orthogonal, with thermal methods based on intramolecular interaction and shear device stability based on localized unfolding revealing less stable regions that drive aggregation. Molecular modeling shows the modifications' effects on the antibody structures and indicates a possible role for Fc conformation and Fab-Fc docking in determining suspended protein stability. The data introduce the PDC value as an orthogonal stability indicator, complementary to traditional thermal methods, allowing lead antibody selection based on a more full understanding of process stability.

SUBMITTER: Tavakoli-Keshe R 

PROVIDER: S-EPMC4263191 | biostudies-literature | 2014 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Understanding the relationship between biotherapeutic protein stability and solid-liquid interfacial shear in constant region mutants of IgG1 and IgG4.

Tavakoli-Keshe Roumteen R   Phillips Jonathan J JJ   Turner Richard R   Bracewell Daniel G DG  

Journal of pharmaceutical sciences 20131219 2


Relative stability of therapeutic antibody candidates is currently evaluated primarily through their response to thermal degradation, yet this technique is not always predictive of stability in manufacture, shipping, and storage. A rotating disk shear device is proposed that produces defined shear conditions at a known solid-liquid interface to measure stability in this environment. Five variants of IgG1 and IgG4 antibodies were created using combinations of two discrete triple amino acid sequen  ...[more]

Similar Datasets

| S-EPMC7002690 | biostudies-literature
| S-EPMC7116851 | biostudies-literature
| S-EPMC10671478 | biostudies-literature
| S-EPMC8471389 | biostudies-literature
| S-EPMC9417913 | biostudies-literature
2009-11-25 | GSE19156 | GEO
| S-EPMC8077608 | biostudies-literature
2020-05-26 | GSE129616 | GEO
| S-EPMC7979908 | biostudies-literature
| S-EPMC8588307 | biostudies-literature