Unknown

Dataset Information

0

Multi-reader multi-case studies using the area under the receiver operator characteristic curve as a measure of diagnostic accuracy: systematic review with a focus on quality of data reporting.


ABSTRACT:

Introduction

We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance.

Methods

We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in consensus then extracted information from primary articles relating to study characteristics and design, methods for reporting study outcomes, model fitting, model assumptions, presentation of results, and interpretation of findings. Results were summarized and presented with a descriptive analysis.

Results

Sixty-four full papers were retrieved from 475 identified citations and ultimately 49 articles describing 51 studies were reviewed and extracted. Radiological imaging was the index test in all. Most studies focused on lesion detection vs. characterization and used less than 10 readers. Only 6 (12%) studies trained readers in advance to use the confidence scale used to build the ROC curve. Overall, description of confidence scores, the ROC curve and its analysis was often incomplete. For example, 21 (41%) studies presented no ROC curve and only 3 (6%) described the distribution of confidence scores. Of 30 studies presenting curves, only 4 (13%) presented the data points underlying the curve, thereby allowing assessment of extrapolation. The mean change in AUC was 0.05 (-0.05 to 0.28). Non-significant change in AUC was attributed to underpowering rather than the diagnostic test failing to improve diagnostic accuracy.

Conclusions

Data reporting in MRMC studies using ROC AUC as an outcome measure is frequently incomplete, hampering understanding of methods and the reliability of results and study conclusions. Authors using this analysis should be encouraged to provide a full description of their methods and results.

SUBMITTER: Dendumrongsup T 

PROVIDER: S-EPMC4277459 | biostudies-literature | 2014

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multi-reader multi-case studies using the area under the receiver operator characteristic curve as a measure of diagnostic accuracy: systematic review with a focus on quality of data reporting.

Dendumrongsup Thaworn T   Plumb Andrew A AA   Halligan Steve S   Fanshawe Thomas R TR   Altman Douglas G DG   Mallett Susan S  

PloS one 20141226 12


<h4>Introduction</h4>We examined the design, analysis and reporting in multi-reader multi-case (MRMC) research studies using the area under the receiver-operating curve (ROC AUC) as a measure of diagnostic performance.<h4>Methods</h4>We performed a systematic literature review from 2005 to 2013 inclusive to identify a minimum 50 studies. Articles of diagnostic test accuracy in humans were identified via their citation of key methodological articles dealing with MRMC ROC AUC. Two researchers in c  ...[more]

Similar Datasets

| S-EPMC7315889 | biostudies-literature
| S-EPMC6768691 | biostudies-literature
| S-EPMC4099021 | biostudies-literature
| S-EPMC3039874 | biostudies-literature
| S-EPMC5133195 | biostudies-literature
| S-EPMC2936710 | biostudies-literature
| S-EPMC9241147 | biostudies-literature
| S-EPMC7163156 | biostudies-literature
| S-EPMC6980576 | biostudies-literature
| S-EPMC3227148 | biostudies-literature