Unknown

Dataset Information

0

Carpal tunnel syndrome assessment with ultrasonography: value of inlet-to-outlet median nerve area ratio in patients versus healthy volunteers.


ABSTRACT: To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS).Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of scaphoid-pisiform) and outlet (the level of the hook of the hamate), and the IOR was calculated for each wrist. Ultrasonography and electrodiagnostic tests were performed under blinded conditions. Electrodiagnostic testing combined with clinical symptoms were considered to be the gold standard test. Receiver operating characteristic (ROC) curves were used to evaluate the diagnostic value between the inlet CSA and IOR.The study population included 16 men and 30 women (mean age, 45.3 years; range, 18-83 years). The control population included 18 men and 26 women (mean age, 50.4 years; range, 18-79 years). The mean inlet CSA was 8.7 mm2 in healthy controls and 14.6mm2 in CTS group (P<0.001). The mean IOR in healthy volunteers (1.0) was smaller than that in patients (1.6, P<0.001). Receiver operating characteristic analysis revealed a diagnostic advantage to using the IOR rather than the inlet CSA (P<0.01). An IOR cutoff value of ? 1.3 would yield 93% specificity and 91% sensitivity in the diagnosis of CTS.The IOR of median nerve area promises to be an effective means in the diagnosis of CTS. A large-scale, randomized controlled trial is required to determine how and when this parameter will be used.

SUBMITTER: Fu T 

PROVIDER: S-EPMC4305299 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Carpal tunnel syndrome assessment with ultrasonography: value of inlet-to-outlet median nerve area ratio in patients versus healthy volunteers.

Fu Tengfei T   Cao Manlin M   Liu Fang F   Zhu Jiaan J   Ye Dongmei D   Feng Xianxuan X   Xu Yiming Y   Wang Gang G   Bai Yuehong Y  

PloS one 20150124 1


<h4>Objective</h4>To evaluate the diagnostic value of the Inlet-to-outlet median nerve area ratio (IOR) in patients with clinically and electrophysiologically confirmed carpal tunnel syndrome (CTS).<h4>Methods</h4>Forty-six wrists in 46 consecutive patients with clinical and electrodiagnostic evidence of CTS and forty-four wrists in 44 healthy volunteers were examined with ultrasonography. The cross-sectional area (CSA) of the median nerve was measured at the carpal tunnel inlet (the level of sc  ...[more]

Similar Datasets

| S-EPMC6610846 | biostudies-literature
| S-EPMC9011265 | biostudies-literature
| S-EPMC6768738 | biostudies-literature
| S-EPMC8236373 | biostudies-literature
| S-EPMC6187921 | biostudies-other
| S-EPMC4320094 | biostudies-literature
| S-EPMC8169596 | biostudies-literature
| S-EPMC5722677 | biostudies-literature
| S-EPMC6718919 | biostudies-literature
| S-EPMC10764211 | biostudies-literature