Unknown

Dataset Information

0

High resolution live cell Raman imaging using subcellular organelle-targeting SERS-sensitive gold nanoparticles with highly narrow intra-nanogap.


ABSTRACT: We report a method to achieve high speed and high resolution live cell Raman images using small spherical gold nanoparticles with highly narrow intra-nanogap structures responding to NIR excitation (785 nm) and high-speed confocal Raman microscopy. The three different Raman-active molecules placed in the narrow intra-nanogap showed a strong and uniform Raman intensity in solution even under transient exposure time (10 ms) and low input power of incident laser (200 ?W), which lead to obtain high-resolution single cell image within 30 s without inducing significant cell damage. The high resolution Raman image showed the distributions of gold nanoparticles for their targeted sites such as cytoplasm, mitochondria, or nucleus. The high speed Raman-based live cell imaging allowed us to monitor rapidly changing cell morphologies during cell death induced by the addition of highly toxic KCN solution to cells. These results strongly suggest that the use of SERS-active nanoparticle can greatly improve the current temporal resolution and image quality of Raman-based cell images enough to obtain the detailed cell dynamics and/or the responses of cells to potential drug molecules.

SUBMITTER: Kang JW 

PROVIDER: S-EPMC4356631 | biostudies-literature | 2015 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

High resolution live cell Raman imaging using subcellular organelle-targeting SERS-sensitive gold nanoparticles with highly narrow intra-nanogap.

Kang Jeon Woong JW   So Peter T C PT   Dasari Ramachandra R RR   Lim Dong-Kwon DK  

Nano letters 20150211 3


We report a method to achieve high speed and high resolution live cell Raman images using small spherical gold nanoparticles with highly narrow intra-nanogap structures responding to NIR excitation (785 nm) and high-speed confocal Raman microscopy. The three different Raman-active molecules placed in the narrow intra-nanogap showed a strong and uniform Raman intensity in solution even under transient exposure time (10 ms) and low input power of incident laser (200 μW), which lead to obtain high-  ...[more]

Similar Datasets

| S-EPMC6523801 | biostudies-literature
| S-EPMC9665105 | biostudies-literature
| S-EPMC9063784 | biostudies-literature
| S-EPMC10391707 | biostudies-literature
| S-EPMC5833005 | biostudies-literature
| S-EPMC5541563 | biostudies-literature
| S-EPMC8402271 | biostudies-literature
| S-EPMC10676777 | biostudies-literature
| S-EPMC9419194 | biostudies-literature
| S-EPMC4022294 | biostudies-literature