Unknown

Dataset Information

0

Real-time sequence-validated loop-mediated isothermal amplification assays for detection of Middle East respiratory syndrome coronavirus (MERS-CoV).


ABSTRACT: The Middle East respiratory syndrome coronavirus (MERS-CoV), an emerging human coronavirus, causes severe acute respiratory illness with a 35% mortality rate. In light of the recent surge in reported infections we have developed asymmetric five-primer reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for detection of MERS-CoV. Isothermal amplification assays will facilitate the development of portable point-of-care diagnostics that are crucial for management of emerging infections. The RT-LAMP assays are designed to amplify MERS-CoV genomic loci located within the open reading frame (ORF)1a and ORF1b genes and upstream of the E gene. Additionally we applied one-step strand displacement probes (OSD) for real-time sequence-specific verification of LAMP amplicons. Asymmetric amplification effected by incorporating a single loop primer in each assay accelerated the time-to-result of the OSD-RT-LAMP assays. The resulting assays could detect 0.02 to 0.2 plaque forming units (PFU) (5 to 50 PFU/ml) of MERS-CoV in infected cell culture supernatants within 30 to 50 min and did not cross-react with common human respiratory pathogens.

SUBMITTER: Bhadra S 

PROVIDER: S-EPMC4391951 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-time sequence-validated loop-mediated isothermal amplification assays for detection of Middle East respiratory syndrome coronavirus (MERS-CoV).

Bhadra Sanchita S   Jiang Yu Sherry YS   Kumar Mia R MR   Johnson Reed F RF   Hensley Lisa E LE   Ellington Andrew D AD  

PloS one 20150409 4


The Middle East respiratory syndrome coronavirus (MERS-CoV), an emerging human coronavirus, causes severe acute respiratory illness with a 35% mortality rate. In light of the recent surge in reported infections we have developed asymmetric five-primer reverse transcription loop-mediated isothermal amplification (RT-LAMP) assays for detection of MERS-CoV. Isothermal amplification assays will facilitate the development of portable point-of-care diagnostics that are crucial for management of emergi  ...[more]

Similar Datasets

| S-EPMC4132226 | biostudies-literature
2014-06-10 | E-GEOD-55023 | biostudies-arrayexpress
2014-06-10 | GSE56189 | GEO
2014-06-10 | GSE55023 | GEO
| S-EPMC7110516 | biostudies-literature
| S-EPMC7166982 | biostudies-literature
| S-EPMC7100557 | biostudies-literature
| S-EPMC7125975 | biostudies-literature
| S-EPMC7113683 | biostudies-literature
| S-EPMC7106011 | biostudies-literature