Effect of blood vessel segmentation on the outcome of electroporation-based treatments of liver tumors.


ABSTRACT: Electroporation-based treatments rely on increasing the permeability of the cell membrane by high voltage electric pulses applied to tissue via electrodes. To ensure that the whole tumor is covered with sufficiently high electric field, accurate numerical models are built based on individual patient anatomy. Extraction of patient's anatomy through segmentation of medical images inevitably produces some errors. In order to ensure the robustness of treatment planning, it is necessary to evaluate the potential effect of such errors on the electric field distribution. In this work we focus on determining the effect of errors in automatic segmentation of hepatic vessels on the electric field distribution in electroporation-based treatments in the liver. First, a numerical analysis was performed on a simple 'sphere and cylinder' model for tumors and vessels of different sizes and relative positions. Second, an analysis of two models extracted from medical images of real patients in which we introduced variations of an error of the automatic vessel segmentation method was performed. The results obtained from a simple model indicate that ignoring the vessels when calculating the electric field distribution can cause insufficient coverage of the tumor with electric fields. Results of this study indicate that this effect happens for small (10 mm) and medium-sized (30 mm) tumors, especially in the absence of a central electrode inserted in the tumor. The results obtained from the real-case models also show higher negative impact of automatic vessel segmentation errors on the electric field distribution when the central electrode is absent. However, the average error of the automatic vessel segmentation did not have an impact on the electric field distribution if the central electrode was present. This suggests the algorithm is robust enough to be used in creating a model for treatment parameter optimization, but with a central electrode.

SUBMITTER: Marcan M 

PROVIDER: S-EPMC4420486 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC3732275 | biostudies-literature
| S-EPMC4110083 | biostudies-literature
| S-EPMC9657605 | biostudies-literature
| S-EPMC7465806 | biostudies-literature
| S-EPMC6238769 | biostudies-other
| S-EPMC8172291 | biostudies-literature
| S-EPMC7809294 | biostudies-literature
| S-EPMC9352679 | biostudies-literature
| S-EPMC3514699 | biostudies-literature
| S-EPMC8666138 | biostudies-literature