Unknown

Dataset Information

0

Intraoperative simulation of remnant liver function during anatomic liver resection with indocyanine green clearance (LiMON) measurements.


ABSTRACT:

Objective

Post-hepatectomy liver failure (PHLF) is the major cause of death following liver resection. The aim of this study was to evaluate the feasibility of an intraoperative simulation of post-resection liver function.

Methods

Intraoperative liver function was measured by indocyanine green (ICG) clearance using the LiMON technology. In 20 patients undergoing anatomic liver resection, ICG plasma disappearance rate (PDR (%/min) and ICG retention at 15?min (R15 ) (%) were measured immediately after the induction of anaesthesia (t0 ), after selective arterial and portovenous inflow trial clamping (TC) of the resected liver segments (t1 ), after the completion of resection (t2 ) and before the closure of the abdominal cavity (t3 ).

Results

The median baseline (t0 ) PDR was 16.5%/min. Trial clamping of the inflow (t1 ) resulted in a significant reduction in PDR to 10.5%/min. Results under TC were similar to those obtained after resection (t2 ) (median PDR: 10.5%/min). Linear regression modelling showed that post-resection liver volume could be accurately predicted by TC of liver inflow (P < 0.0001), but not by determining the resected liver volume. Simulated post-resection liver function under TC correlated well with PHLF and length of hospital stay.

Conclusions

Intraoperative ICG clearance measurements allow real-time monitoring of intraoperative liver function during surgery. Trial clamping of arterial and portovenous inflow accurately predicts immediate post-resection liver function. The intraoperative measurement of liver function and simulation of post-resection liver function may help to avoid PHLF.

SUBMITTER: Thomas MN 

PROVIDER: S-EPMC4430775 | biostudies-literature | 2015 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Intraoperative simulation of remnant liver function during anatomic liver resection with indocyanine green clearance (LiMON) measurements.

Thomas Michael N MN   Weninger Ernst E   Angele Martin M   Bösch Florian F   Pratschke Sebastian S   Andrassy Joachim J   Rentsch Markus M   Stangl Manfred M   Hartwig Werner W   Werner Jens J   Guba Markus M  

HPB : the official journal of the International Hepato Pancreato Biliary Association 20150108 6


<h4>Objective</h4>Post-hepatectomy liver failure (PHLF) is the major cause of death following liver resection. The aim of this study was to evaluate the feasibility of an intraoperative simulation of post-resection liver function.<h4>Methods</h4>Intraoperative liver function was measured by indocyanine green (ICG) clearance using the LiMON technology. In 20 patients undergoing anatomic liver resection, ICG plasma disappearance rate (PDR (%/min) and ICG retention at 15 min (R15 ) (%) were measure  ...[more]

Similar Datasets

| S-EPMC5094749 | biostudies-literature
| S-EPMC6557886 | biostudies-other
| S-EPMC7426192 | biostudies-literature
| S-EPMC6476649 | biostudies-literature
| S-EPMC10914702 | biostudies-literature
| S-EPMC2020684 | biostudies-other
| S-EPMC7263840 | biostudies-literature
| S-EPMC4849298 | biostudies-literature
| S-EPMC9111972 | biostudies-literature
| S-EPMC4224503 | biostudies-literature