Unknown

Dataset Information

0

Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis.


ABSTRACT:

Background

i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps.

Objective

Our aim of this study was to perform a meta-analysis of published data to establish the diagnostic accuracy of i-Scan for optical diagnosis of colonic polyps.

Methods

We searched PubMed, Medline, Elsevier ScienceDirect and Cochrane Library databases. We used a bivariate meta-analysis following a random effects model to summarize the data and plotted hierarchical summary receiver-operating characteristic (HSROC) curves. The area under the HSROC curve (AUC) serves as an indicator of the diagnostic accuracy.

Results

The meta-analysis included a total of 925 patients and 2312 polyps. For the overall studies, the area under the HSROC curve was 0.96. The summary sensitivity was 90.4% (95%CI 85%-94.1%) and specificity was 90.9% (95%CI 84.3%-94.9%). In 11 studies predicting polyps histology in real-time, the summary sensitivity and specificity was 91.5% (95%CI 85.7%-95.1%) and 92.1% (95%CI 84.5%-96.1%), respectively, with the AUC of 0.97. For three different diagnostic criteria (Kudo, NICE, others), the sensitivity was 86.3%, 93.0%, 85.0%, respectively and specificity was 84.8%, 94.4%, 91.8%, respectively.

Conclusions

Endoscopic diagnosis with i-Scan has accurate optical diagnostic performance to differentiate neoplastic from non-neoplastic polyps with an area under the HSROC curve exceeding 0.90. Both the sensitivity and specificity for diagnosing colonic polyps are over 90%.

SUBMITTER: Guo CG 

PROVIDER: S-EPMC4433272 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of i-Scan for Optical Diagnosis of Colonic Polyps: A Meta-Analysis.

Guo Chuan-Guo CG   Ji Rui R   Li Yan-Qing YQ  

PloS one 20150515 5


<h4>Background</h4>i-Scan is a novel virtual chromoendoscopy system designed to enhance surface and vascular patterns to improve optical diagnostic performance. Numerous prospective studies have been done to evaluate the accuracy of i-Scan in differentiating colonic neoplasms from non-neoplasms. i-Scan could be an effective endoscopic technique for optical diagnosis of colonic polyps.<h4>Objective</h4>Our aim of this study was to perform a meta-analysis of published data to establish the diagnos  ...[more]

Similar Datasets

| 2156753 | ecrin-mdr-crc
| S-EPMC8062231 | biostudies-literature
| S-EPMC8319784 | biostudies-literature
| S-EPMC8062223 | biostudies-literature
| S-EPMC9210775 | biostudies-literature
| S-EPMC6584889 | biostudies-literature
| S-EPMC7964662 | biostudies-literature
| S-EPMC5754143 | biostudies-literature
| S-EPMC4040745 | biostudies-literature
| S-EPMC5443513 | biostudies-literature