Comparison of centric and reverse-centric trajectories for highly accelerated three-dimensional saturation recovery cardiac perfusion imaging.


ABSTRACT: Highly undersampled three-dimensional (3D) saturation-recovery sequences are affected by k-space trajectory since the magnetization does not reach steady state during the acquisition and the slab excitation profile yields different flip angles in different slices. This study compares centric and reverse-centric 3D cardiac perfusion imaging.An undersampled (98 phase encodes) 3D ECG-gated saturation-recovery sequence that alternates centric and reverse-centric acquisitions each time frame was used to image phantoms and in vivo subjects. Flip angle variation across the slices was measured, and contrast with each trajectory was analyzed via Bloch simulation.Significant variations in flip angle were observed across slices, leading to larger signal variation across slices for the centric acquisition. In simulation, severe transient artifacts were observed when using the centric trajectory with higher flip angles, placing practical limits on the maximum flip angle used. The reverse-centric trajectory provided less contrast, but was more robust to flip angle variations.Both of the k-space trajectories can provide reasonable image quality. The centric trajectory can have higher CNR, but is more sensitive to flip angle variation. The reverse-centric trajectory is more robust to flip angle variation.

SUBMITTER: Wang H 

PROVIDER: S-EPMC4456305 | biostudies-literature | 2015 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of centric and reverse-centric trajectories for highly accelerated three-dimensional saturation recovery cardiac perfusion imaging.

Wang Haonan H   Bangerter Neal K NK   Park Daniel J DJ   Adluru Ganesh G   Kholmovski Eugene G EG   Xu Jian J   DiBella Edward E  

Magnetic resonance in medicine 20141006 4


<h4>Purpose</h4>Highly undersampled three-dimensional (3D) saturation-recovery sequences are affected by k-space trajectory since the magnetization does not reach steady state during the acquisition and the slab excitation profile yields different flip angles in different slices. This study compares centric and reverse-centric 3D cardiac perfusion imaging.<h4>Methods</h4>An undersampled (98 phase encodes) 3D ECG-gated saturation-recovery sequence that alternates centric and reverse-centric acqui  ...[more]

Similar Datasets

| S-EPMC4548835 | biostudies-literature
2022-12-21 | GSE183137 | GEO
| S-EPMC6400099 | biostudies-literature
| S-EPMC6641586 | biostudies-literature
| S-EPMC6561940 | biostudies-literature
| S-EPMC9321550 | biostudies-literature
| S-EPMC2614420 | biostudies-literature
| S-EPMC4860174 | biostudies-literature
| S-EPMC7386730 | biostudies-literature
| S-EPMC6740170 | biostudies-literature