Unknown

Dataset Information

0

Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.


ABSTRACT:

Purpose

Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes.

Methods

Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with tertiary hyperparathyroidism. Imaging findings were correlated with surgical results. Concomitant thyroid disease, pre- and postoperative laboratory measurements, histopathological results, type and duration of surgery were assessed.

Results

In primary hyperparathyroidism, SPECT had a sensitivity of 80% and a positive predictive value of 93% in patient-based analysis. Specificity was 99% in lesion-based analysis. Patients with positive SPECT elicit higher levels of parathyroid hormone and higher weight of resected parathyroids than SPECT-negative patients. Duration of parathyroid surgery was on average, approximately 40 minutes shorter in SPECT-positive than in SPECT-negative patients (89 ± 46 vs. 129 ± 41 minutes, p = 0.006); 86% of SPECT-positive and 50% of SPECT-negative patients had minimal invasive surgery (p = 0.021). SPECT had lower sensitivity (60%) in patients with tertiary hyperparathyroidism; however, 90% of these patients had multiple lesions and all of these patients had bilateral lesions.

Conclusion

Dual-isotope SPECT with 99mTc-tetrofosmin and 123I sodium iodide has a high diagnostic value in patients with primary hyperparathyroidism and allows for saving of operation time. Higher levels of parathyroid hormone and higher glandular weight facilitated detection of parathyroid lesion. Diagnostic accuracy of preoperative imaging was lower in patients with tertiary hyperparathyroidism.

SUBMITTER: Sommerauer M 

PROVIDER: S-EPMC4469677 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sensitivity and Specificity of Dual-Isotope 99mTc-Tetrofosmin and 123I Sodium Iodide Single Photon Emission Computed Tomography (SPECT) in Hyperparathyroidism.

Sommerauer Michael M   Graf Carmen C   Schäfer Niklaus N   Huber Gerhard G   Schneider Paul P   Wüthrich Rudolf R   Schmid Christoph C   Steinert Hans H  

PloS one 20150616 6


<h4>Purpose</h4>Despite recommendations for 99mTc-tetrofosmin dual tracer imaging for hyperparathyroidism in current guidelines, no report was published on dual-isotope 99mTc-tetrofosmin and 123I sodium iodide single-photon-emission-computed-tomography (SPECT). We evaluated diagnostic accuracy and the impact of preoperative SPECT on the surgical procedures and disease outcomes.<h4>Methods</h4>Analysis of 70 consecutive patients with primary hyperparathyroidism and 20 consecutive patients with te  ...[more]

Similar Datasets

| S-EPMC7808361 | biostudies-literature
| S-EPMC9553767 | biostudies-literature
| S-EPMC4414206 | biostudies-literature
| S-EPMC7483712 | biostudies-literature
| S-EPMC11320519 | biostudies-literature
| S-EPMC3785531 | biostudies-other
| S-EPMC11008844 | biostudies-literature
| S-EPMC4980098 | biostudies-literature
| S-EPMC6933043 | biostudies-literature
| S-EPMC5721092 | biostudies-literature