Upgrade of a Scanning Confocal Microscope to a Single-Beam Path STED Microscope.


ABSTRACT: By overcoming the diffraction limit in light microscopy, super-resolution techniques, such as stimulated emission depletion (STED) microscopy, are experiencing an increasing impact on life sciences. High costs and technically demanding setups, however, may still hinder a wider distribution of this innovation in biomedical research laboratories. As far-field microscopy is the most widely employed microscopy modality in the life sciences, upgrading already existing systems seems to be an attractive option for achieving diffraction-unlimited fluorescence microscopy in a cost-effective manner. Here, we demonstrate the successful upgrade of a commercial time-resolved confocal fluorescence microscope to an easy-to-align STED microscope in the single-beam path layout, previously proposed as "easy-STED", achieving lateral resolution < ?/10 corresponding to a five-fold improvement over a confocal modality. For this purpose, both the excitation and depletion laser beams pass through a commercially available segmented phase plate that creates the STED-doughnut light distribution in the focal plane, while leaving the excitation beam unaltered when implemented into the joint beam path. Diffraction-unlimited imaging of 20 nm-sized fluorescent beads as reference were achieved with the wavelength combination of 635 nm excitation and 766 nm depletion. To evaluate the STED performance in biological systems, we compared the popular phalloidin-coupled fluorescent dyes Atto647N and Abberior STAR635 by labeling F-actin filaments in vitro as well as through immunofluorescence recordings of microtubules in a complex epithelial tissue. Here, we applied a recently proposed deconvolution approach and showed that images obtained from time-gated pulsed STED microscopy may benefit concerning the signal-to-background ratio, from the joint deconvolution of sub-images with different spatial information which were extracted from offline time gating.

SUBMITTER: Klauss A 

PROVIDER: S-EPMC4475078 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Upgrade of a Scanning Confocal Microscope to a Single-Beam Path STED Microscope.

Klauss André A   König Marcelle M   Hille Carsten C  

PloS one 20150619 6


By overcoming the diffraction limit in light microscopy, super-resolution techniques, such as stimulated emission depletion (STED) microscopy, are experiencing an increasing impact on life sciences. High costs and technically demanding setups, however, may still hinder a wider distribution of this innovation in biomedical research laboratories. As far-field microscopy is the most widely employed microscopy modality in the life sciences, upgrading already existing systems seems to be an attractiv  ...[more]

Similar Datasets

| S-EPMC1853322 | biostudies-literature
| S-EPMC3380810 | biostudies-literature
| S-EPMC6115396 | biostudies-literature
| S-EPMC9374259 | biostudies-literature
| S-EPMC4813191 | biostudies-literature
| S-EPMC2587633 | biostudies-literature
| S-EPMC4667224 | biostudies-literature
| S-EPMC3689173 | biostudies-other
| S-EPMC4491170 | biostudies-literature
| S-EPMC5081072 | biostudies-literature