Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.


ABSTRACT: Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth of linear transducer arrays applied in full-view PACT are low, limiting the spatial resolutions of the reconstructed images. Here, we present a multiview high-frequency PACT imaging system implemented with a commercial 40-MHz central frequency linear transducer array. By rotating the object through multiple angles with respect to the linear transducer array, we acquired full-view photoacoustic pressure measurements. Further, to quantify the unipolar initial pressures and overcome the limitations of the single-view Hilbert transformation, we developed a multiview Hilbert transformation method. The in-plane spatial resolution of this full-view linear-array PACT was quantified to be isotropically 60???m within a 10×10??mm² field of view. The system was demonstrated by imaging both a leaf skeleton and a zebrafish in vivo.

SUBMITTER: Li G 

PROVIDER: S-EPMC4481023 | biostudies-literature | 2015 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array.

Li Guo G   Li Lei L   Zhu Liren L   Xia Jun J   Wang Lihong V LV  

Journal of biomedical optics 20150601 6


Due to their low cost, hand-held convenience, wide selection of bandwidths, and ultrasound imaging capability, linear ultrasonic transducer arrays have been widely studied for photoacoustic computed tomography (PACT). As linear-array PACT suffers from a limited view, full-view imaging requires either the transducer or the object to be rotated. So far, both the central frequencies and bandwidth of linear transducer arrays applied in full-view PACT are low, limiting the spatial resolutions of the  ...[more]

Similar Datasets

| S-EPMC6388697 | biostudies-literature
| S-EPMC6380242 | biostudies-literature
| S-EPMC7096763 | biostudies-literature
| S-EPMC9198371 | biostudies-literature
| S-EPMC9161237 | biostudies-literature
| S-EPMC5995136 | biostudies-literature
| S-EPMC6003984 | biostudies-literature
| S-EPMC4429303 | biostudies-literature
| S-EPMC7411732 | biostudies-literature
| S-EPMC3881607 | biostudies-literature