Acoustothermal heating of polydimethylsiloxane microfluidic system.


ABSTRACT: We report an observation of rapid (exceeding 2,000 K/s) heating of polydimethylsiloxane (PDMS), one of the most popular microchannel materials, under cyclic loadings at high (~MHz) frequencies. A microheater was developed based on the finding. The heating mechanism utilized vibration damping in PDMS induced by sound waves that were generated and precisely controlled using a conventional surface acoustic wave (SAW) microfluidic system. The refraction of SAW into the PDMS microchip, called the leaky SAW, takes a form of bulk wave and rapidly heats the microchannels in a volumetric manner. The penetration depths were measured to range from 210 ?m to 1290 ?m, enough to cover most sizes of microchannels. The energy conversion efficiency was SAW frequency-dependent and measured to be the highest at around 30 MHz. Independent actuation of each interdigital transducer (IDT) enabled independent manipulation of SAWs, permitting spatiotemporal control of temperature on the microchip. All the advantages of this microheater facilitated a two-step continuous flow polymerase chain reaction (CFPCR) to achieve the billion-fold amplification of a 134 bp DNA amplicon in less than 3 min.

SUBMITTER: Ha BH 

PROVIDER: S-EPMC4490350 | biostudies-literature | 2015 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Acoustothermal heating of polydimethylsiloxane microfluidic system.

Ha Byung Hang BH   Lee Kang Soo KS   Destgeer Ghulam G   Park Jinsoo J   Choung Jin Seung JS   Jung Jin Ho JH   Shin Jennifer Hyunjong JH   Sung Hyung Jin HJ  

Scientific reports 20150703


We report an observation of rapid (exceeding 2,000 K/s) heating of polydimethylsiloxane (PDMS), one of the most popular microchannel materials, under cyclic loadings at high (~MHz) frequencies. A microheater was developed based on the finding. The heating mechanism utilized vibration damping in PDMS induced by sound waves that were generated and precisely controlled using a conventional surface acoustic wave (SAW) microfluidic system. The refraction of SAW into the PDMS microchip, called the lea  ...[more]

Similar Datasets

| S-EPMC2792742 | biostudies-literature
| S-EPMC3327513 | biostudies-literature
| S-EPMC5343277 | biostudies-literature
| S-EPMC9148048 | biostudies-literature
| S-EPMC3365910 | biostudies-other
| S-EPMC4000390 | biostudies-other
| S-EPMC9188593 | biostudies-literature
| S-EPMC8812517 | biostudies-literature
| S-EPMC7692984 | biostudies-literature
| S-EPMC5678186 | biostudies-literature