Unknown

Dataset Information

0

Criterion Validation Testing of Clinical Metrology Instruments for Measuring Degenerative Joint Disease Associated Mobility Impairment in Cats.


ABSTRACT:

Introduction

Degenerative joint disease and associated pain are common in cats, particularly in older cats. There is a need for treatment options, however evaluation of putative therapies is limited by a lack of suitable, validated outcome measures that can be used in the target population of client owned cats. The objectives of this study were to evaluate low-dose daily meloxicam for the treatment of pain associated with degenerative joint disease in cats, and further validate two clinical metrology instruments, the Feline Musculoskeletal Pain Index (FMPI) and the Client Specific Outcome Measures (CSOM).

Methods

Sixty-six client owned cats with degenerative joint disease and owner-reported impairments in mobility were screened and enrolled into a double-masked, placebo-controlled, randomized clinical trial. Following a run-in baseline period, cats were given either placebo or meloxicam for 21 days, then in a masked washout, cats were all given placebo for 21 days. Subsequently, cats were given the opposite treatment, placebo or meloxicam, for 21 days. Cats wore activity monitors throughout the study, owners completed clinical metrology instruments following each period.

Results

Activity counts were increased in cats during treatment with daily meloxicam (p<0.0001) compared to baseline. The FMPI results and activity count data offer concurrent validation for the FMPI, though the relationship between baseline activity counts and FMPI scores at baseline was poor (R2=0.034). The CSOM did not show responsiveness for improvement in this study, and the relationship between baseline activity counts and CSOM scores at baseline was similarly poor (R2=0.042).

Conclusions

Refinements to the FMPI, including abbreviation of the instrument and scoring as percent of possible score are recommended. This study offered further validation of the FMPI as a clinical metrology instrument for use in detecting therapeutic efficacy in cats with degenerative joint disease.

SUBMITTER: Gruen ME 

PROVIDER: S-EPMC4498683 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Criterion Validation Testing of Clinical Metrology Instruments for Measuring Degenerative Joint Disease Associated Mobility Impairment in Cats.

Gruen Margaret E ME   Gruen Margaret E ME   Griffith Emily H EH   Thomson Andrea E AE   Simpson Wendy W   Lascelles B Duncan X BD  

PloS one 20150710 7


<h4>Introduction</h4>Degenerative joint disease and associated pain are common in cats, particularly in older cats. There is a need for treatment options, however evaluation of putative therapies is limited by a lack of suitable, validated outcome measures that can be used in the target population of client owned cats. The objectives of this study were to evaluate low-dose daily meloxicam for the treatment of pain associated with degenerative joint disease in cats, and further validate two clini  ...[more]

Similar Datasets

| S-EPMC7328229 | biostudies-literature
| S-EPMC5522727 | biostudies-literature
| S-EPMC7736399 | biostudies-literature
| S-EPMC5913915 | biostudies-literature
| S-EPMC4414065 | biostudies-literature
| S-EPMC5242440 | biostudies-literature
| S-EPMC8636455 | biostudies-literature
| S-EPMC3135422 | biostudies-literature
| S-EPMC8032665 | biostudies-literature
| S-EPMC2970670 | biostudies-literature