Unknown

Dataset Information

0

Ultrasensitive measurement of huntingtin protein in cerebrospinal fluid demonstrates increase with Huntington disease stage and decrease following brain huntingtin suppression.


ABSTRACT: Quantitation of huntingtin protein in the brain is needed, both as a marker of Huntington disease (HD) progression and for use in clinical gene silencing trials. Measurement of huntingtin in cerebrospinal fluid could be a biomarker of brain huntingtin, but traditional protein quantitation methods have failed to detect huntingtin in cerebrospinal fluid. Using micro-bead based immunoprecipitation and flow cytometry (IP-FCM), we have developed a highly sensitive mutant huntingtin detection assay. The sensitivity of huntingtin IP-FCM enables accurate detection of mutant huntingtin protein in the cerebrospinal fluid of HD patients and model mice, demonstrating that mutant huntingtin levels in cerebrospinal fluid reflect brain levels, increasing with disease stage and decreasing following brain huntingtin suppression. This technique has potential applications as a research tool and as a clinical biomarker.

SUBMITTER: Southwell AL 

PROVIDER: S-EPMC4502413 | biostudies-literature | 2015 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrasensitive measurement of huntingtin protein in cerebrospinal fluid demonstrates increase with Huntington disease stage and decrease following brain huntingtin suppression.

Southwell Amber L AL   Smith Stephen E P SE   Davis Tessa R TR   Caron Nicholas S NS   Villanueva Erika B EB   Xie Yuanyun Y   Collins Jennifer A JA   Ye Min Li ML   Sturrock Aaron A   Leavitt Blair R BR   Schrum Adam G AG   Hayden Michael R MR  

Scientific reports 20150715


Quantitation of huntingtin protein in the brain is needed, both as a marker of Huntington disease (HD) progression and for use in clinical gene silencing trials. Measurement of huntingtin in cerebrospinal fluid could be a biomarker of brain huntingtin, but traditional protein quantitation methods have failed to detect huntingtin in cerebrospinal fluid. Using micro-bead based immunoprecipitation and flow cytometry (IP-FCM), we have developed a highly sensitive mutant huntingtin detection assay. T  ...[more]

Similar Datasets

| S-EPMC4718563 | biostudies-literature
| S-EPMC9746690 | biostudies-literature
2020-05-10 | GSE150174 | GEO
| S-EPMC6446047 | biostudies-literature
| S-EPMC8186543 | biostudies-literature
| S-EPMC4463213 | biostudies-literature
| S-EPMC2649809 | biostudies-literature
| PRJNA856347 | ENA
| S-EPMC9535588 | biostudies-literature
| S-EPMC4160241 | biostudies-literature