Development of a cobinamide-based end-of-service-life indicator for detection of hydrogen cyanide gas.
Ontology highlight
ABSTRACT: We describe an inexpensive paper-based sensor for rapid detection of low concentrations (ppm) of hydrogen cyanide gas. A piece of filter paper pre-spotted with a dilute monocyanocobinamide [CN(H2O)Cbi] solution was placed on the end of a bifurcated optical fiber and the reflectance spectrum of the CN(H2O)Cbi was monitored during exposure to 1.0-10.0 ppm hydrogen cyanide gas. Formation of dicyanocobinamide yielded a peak at 583 nm with a simultaneous decrease in reflectance from 450-500 nm. Spectral changes were monitored as a function of time at several relative humidity values: 25, 50, and 85% relative humidity. With either cellulose or glass fiber papers, spectral changes occurred within 10 s of exposure to 5.0 ppm hydrogen cyanide gas (NIOSH recommended short-term
SUBMITTER: Greenawald LA
PROVIDER: S-EPMC4511729 | biostudies-literature | 2015 Dec
REPOSITORIES: biostudies-literature
ACCESS DATA