Unknown

Dataset Information

0

Diagnostic concordance among pathologists interpreting breast biopsy specimens.


ABSTRACT: A breast pathology diagnosis provides the basis for clinical treatment and management decisions; however, its accuracy is inadequately understood.To quantify the magnitude of diagnostic disagreement among pathologists compared with a consensus panel reference diagnosis and to evaluate associated patient and pathologist characteristics.Study of pathologists who interpret breast biopsies in clinical practices in 8 US states.Participants independently interpreted slides between November 2011 and May 2014 from test sets of 60 breast biopsies (240 total cases, 1 slide per case), including 23 cases of invasive breast cancer, 73 ductal carcinoma in situ (DCIS), 72 with atypical hyperplasia (atypia), and 72 benign cases without atypia. Participants were blinded to the interpretations of other study pathologists and consensus panel members. Among the 3 consensus panel members, unanimous agreement of their independent diagnoses was 75%, and concordance with the consensus-derived reference diagnoses was 90.3%.The proportions of diagnoses overinterpreted and underinterpreted relative to the consensus-derived reference diagnoses were assessed.Sixty-five percent of invited, responding pathologists were eligible and consented to participate. Of these, 91% (N?=?115) completed the study, providing 6900 individual case diagnoses. Compared with the consensus-derived reference diagnosis, the overall concordance rate of diagnostic interpretations of participating pathologists was 75.3% (95% CI, 73.4%-77.0%; 5194 of 6900 interpretations). Among invasive carcinoma cases (663 interpretations), 96% (95% CI, 94%-97%) were concordant, and 4% (95% CI, 3%-6%) were underinterpreted; among DCIS cases (2097 interpretations), 84% (95% CI, 82%-86%) were concordant, 3% (95% CI, 2%-4%) were overinterpreted, and 13% (95% CI, 12%-15%) were underinterpreted; among atypia cases (2070 interpretations), 48% (95% CI, 44%-52%) were concordant, 17% (95% CI, 15%-21%) were overinterpreted, and 35% (95% CI, 31%-39%) were underinterpreted; and among benign cases without atypia (2070 interpretations), 87% (95% CI, 85%-89%) were concordant and 13% (95% CI, 11%-15%) were overinterpreted. Disagreement with the reference diagnosis was statistically significantly higher among biopsies from women with higher (n?=?122) vs lower (n?=?118) breast density on prior mammograms (overall concordance rate, 73% [95% CI, 71%-75%] for higher vs 77% [95% CI, 75%-80%] for lower, P?

SUBMITTER: Elmore JG 

PROVIDER: S-EPMC4516388 | biostudies-literature | 2015 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Importance</h4>A breast pathology diagnosis provides the basis for clinical treatment and management decisions; however, its accuracy is inadequately understood.<h4>Objectives</h4>To quantify the magnitude of diagnostic disagreement among pathologists compared with a consensus panel reference diagnosis and to evaluate associated patient and pathologist characteristics.<h4>Design, setting, and participants</h4>Study of pathologists who interpret breast biopsies in clinical practices in 8 US s  ...[more]

Similar Datasets

| S-EPMC6463485 | biostudies-literature
| S-EPMC9761085 | biostudies-literature
| S-EPMC5572810 | biostudies-literature
| S-EPMC4007232 | biostudies-literature
2018-02-15 | GSE100503 | GEO
| S-EPMC5220610 | biostudies-literature
| S-EPMC9305900 | biostudies-literature
2016-03-29 | GSE73235 | GEO
2022-07-07 | GSE159141 | GEO
| S-EPMC9184404 | biostudies-literature