Unknown

Dataset Information

0

Low-Cost High-Resolution Microendoscopy for the Detection of Esophageal Squamous Cell Neoplasia: An International Trial.


ABSTRACT: Esophageal squamous cell neoplasia has a high mortality rate as a result of late detection. In high-risk regions such as China, screening is performed by Lugol's chromoendoscopy (LCE). LCE has low specificity, resulting in unnecessary tissue biopsy with a subsequent increase in procedure cost and risk. The purpose of this study was to evaluate the accuracy of a novel, low-cost, high-resolution microendoscope (HRME) as an adjunct to LCE.In this prospective trial, 147 consecutive high-risk patients were enrolled from 2 US and 2 Chinese tertiary centers. Three expert and 4 novice endoscopists performed white-light endoscopy followed by LCE and HRME. All optical images were compared with the gold standard of histopathology.By using a per-biopsy analysis, the sensitivity of LCE vs LCE + HRME was 96% vs 91% (P = .0832), specificity was 48% vs 88% (P < .001), positive predictive value was 22% vs 45% (P < .0001), negative predictive value was 98% vs 98% (P = .3551), and overall accuracy was 57% vs 90% (P < .001), respectively. By using a per-patient analysis, the sensitivity of LCE vs LCE + HRME was 100% vs 95% (P = .16), specificity was 29% vs 79% (P < .001), positive predictive value was 32% vs 60%, 100% vs 98%, and accuracy was 47% vs 83% (P < .001). With the use of HRME, 136 biopsies (60%; 95% confidence interval, 53%-66%) could have been spared, and 55 patients (48%; 95% confidence interval, 38%-57%) could have been spared any biopsy.In this trial, HRME improved the accuracy of LCE for esophageal squamous cell neoplasia screening and surveillance. HRME may be a cost-effective optical biopsy adjunct to LCE, potentially reducing unnecessary biopsies and facilitating real-time decision making in globally underserved regions. ClinicalTrials.gov, NCT 01384708.

SUBMITTER: Protano MA 

PROVIDER: S-EPMC4547689 | biostudies-literature | 2015 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background & aims</h4>Esophageal squamous cell neoplasia has a high mortality rate as a result of late detection. In high-risk regions such as China, screening is performed by Lugol's chromoendoscopy (LCE). LCE has low specificity, resulting in unnecessary tissue biopsy with a subsequent increase in procedure cost and risk. The purpose of this study was to evaluate the accuracy of a novel, low-cost, high-resolution microendoscope (HRME) as an adjunct to LCE.<h4>Methods</h4>In this prospectiv  ...[more]

Similar Datasets

| S-EPMC4504008 | biostudies-literature
| S-EPMC4462739 | biostudies-literature
| S-EPMC3494281 | biostudies-literature
| S-EPMC2795438 | biostudies-literature
| S-EPMC9123668 | biostudies-literature
| S-EPMC8633967 | biostudies-literature
| S-EPMC4412137 | biostudies-literature
2020-07-15 | GSE145187 | GEO
| S-EPMC5494775 | biostudies-other