Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.


ABSTRACT: To prospectively examine the feasibility and accuracy of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) activity in the terminal ileum in comparison to Magnetic Resonance Enterography (MRE), using endoscopy as a reference standard.105 consecutive patients with alleged clinically active CD were assessed by MRE and CEUS. CEUS of the terminal ileum was performed using an intravenous microbubble contrast enhancer. Accuracy values of CEUS and MRE for the presence of active terminal ileitis were evaluated using the Receiver Operating Characteristic method, using endoscopic findings as a reference standard. Sensitivity and specificity values of MRE and CEUS were compared by the McNemar test.CEUS was feasible in 98% of patients, MRE in all. Optimal diagnostic accuracy in CEUS was obtained at a peak intensity value of 10%, showing 100% sensitivity, 92% specificity and an accuracy of 99% in demonstrating ileal mucosal inflammation. For MRE, overall sensitivity, specificity and accuracy were, 87%, 100%, and 88%, respectively. CEUS and MRE were highly correlated in assessing length and wall thickness of the terminal ileum. CEUS identified 11 of 16 MRE-detected strictures, but no fistulae.The accuracy of CEUS is comparable to that of MRE in the assessment of active, uncomplicated terminal ileal CD and therefore a valuable bedside alternative to MRE in the follow-up of these patients.

SUBMITTER: Horjus Talabur Horje CS 

PROVIDER: S-EPMC4556376 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Contrast Enhanced Abdominal Ultrasound in the Assessment of Ileal Inflammation in Crohn's Disease: A Comparison with MR Enterography.

Horjus Talabur Horje C S CS   Bruijnen R R   Roovers L L   Groenen M J M MJ   Joosten F B M FB   Wahab P J PJ  

PloS one 20150831 8


<h4>Background and aims</h4>To prospectively examine the feasibility and accuracy of Contrast Enhanced Ultrasound (CEUS) in the assessment of Crohn's disease (CD) activity in the terminal ileum in comparison to Magnetic Resonance Enterography (MRE), using endoscopy as a reference standard.<h4>Methods</h4>105 consecutive patients with alleged clinically active CD were assessed by MRE and CEUS. CEUS of the terminal ileum was performed using an intravenous microbubble contrast enhancer. Accuracy va  ...[more]

Similar Datasets

| S-EPMC6505095 | biostudies-literature
| S-EPMC9576345 | biostudies-literature
| S-EPMC5884912 | biostudies-literature
| S-EPMC5240495 | biostudies-literature
| S-EPMC3259412 | biostudies-literature
| S-EPMC5556127 | biostudies-other
| S-EPMC4101737 | biostudies-literature
| S-EPMC5039714 | biostudies-literature
| S-EPMC11369078 | biostudies-literature
| S-EPMC10235592 | biostudies-literature