Superiority of Graphene over Polymer Coatings for Prevention of Microbially Induced Corrosion.


ABSTRACT: Prevention of microbially induced corrosion (MIC) is of great significance in many environmental applications. Here, we report the use of an ultra-thin, graphene skin (Gr) as a superior anti-MIC coating over two commercial polymeric coatings, Parylene-C (PA) and Polyurethane (PU). We find that Nickel (Ni) dissolution in a corrosion cell with Gr-coated Ni is an order of magnitude lower than that of PA and PU coated electrodes. Electrochemical analysis reveals that the Gr coating offers ~10 and ~100 fold improvement in MIC resistance over PU and PA coatings respectively. This finding is remarkable considering that the Gr coating (1-2?nm) is ~25 and ~4000 times thinner than the PA (40-50?nm), and PU coatings (20-80??m), respectively. Conventional polymer coatings are either non-conformal when deposited or degrade under the action of microbial processes, while the electro-chemically inert graphene coating is both resistant to microbial attack and is extremely conformal and defect-free. Finally, we provide a brief discussion regarding the effectiveness of as-grown vs. transferred graphene films for anti-MIC applications. While the as-grown graphene films are devoid of major defects, wet transfer of graphene is shown to introduce large scale defects that make it less suitable for the current application.

SUBMITTER: Krishnamurthy A 

PROVIDER: S-EPMC4563365 | biostudies-literature | 2015 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Superiority of Graphene over Polymer Coatings for Prevention of Microbially Induced Corrosion.

Krishnamurthy Ajay A   Gadhamshetty Venkataramana V   Mukherjee Rahul R   Natarajan Bharath B   Eksik Osman O   Ali Shojaee S S   Lucca Don A DA   Ren Wencai W   Cheng Hui-Ming HM   Koratkar Nikhil N  

Scientific reports 20150909


Prevention of microbially induced corrosion (MIC) is of great significance in many environmental applications. Here, we report the use of an ultra-thin, graphene skin (Gr) as a superior anti-MIC coating over two commercial polymeric coatings, Parylene-C (PA) and Polyurethane (PU). We find that Nickel (Ni) dissolution in a corrosion cell with Gr-coated Ni is an order of magnitude lower than that of PA and PU coated electrodes. Electrochemical analysis reveals that the Gr coating offers ~10 and ~1  ...[more]

Similar Datasets

| PRJEB18275 | ENA
| S-EPMC4513438 | biostudies-literature
| PRJEB32918 | ENA
| S-EPMC6003706 | biostudies-literature
| PRJEB18457 | ENA
| S-EPMC4352008 | biostudies-literature
| S-EPMC7531442 | biostudies-literature
| S-EPMC6893952 | biostudies-literature
| S-EPMC7277262 | biostudies-literature
| S-EPMC7352741 | biostudies-literature