Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.


ABSTRACT:

Background

In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing.

Methods

Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paired blood samples. For each pair of samples, one was immediately processed and plasma was frozen, and the other was delayed and transported as whole blood before processing and freezing of plasma (similar to the Danish National Birth Cohort). We measured 12 perfluoroalkyl acids and present results for compounds with more than 50% of samples above the lower limit of quantification.

Results

For samples taken in the winter, relative differences between the paired samples ranged between -77 and +38% for individual perfluoroalkyl acids. In most cases concentrations were lower in the delayed and transported samples, e.g. the relative difference was -29% (95% confidence interval -30; -27) for perfluorooctane sulfonate. For perfluorooctanoate there was no difference between the two setups [corresponding estimate 1% (0, 3)]. Differences were negligible in the summer for all compounds.

Conclusions

Transport of blood samples and processing delay, similar to conditions applied in some large, population-based studies, may affect measured perfluoroalkyl acid concentrations, mainly when outdoor temperatures are low. Attention to processing conditions is needed in studies of perfluoroalkyl acid exposure in humans.

SUBMITTER: Bach CC 

PROVIDER: S-EPMC4565678 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Perfluoroalkyl Acid Concentrations in Blood Samples Subjected to Transportation and Processing Delay.

Bach Cathrine Carlsen CC   Henriksen Tine Brink TB   Bossi Rossana R   Bech Bodil Hammer BH   Fuglsang Jens J   Olsen Jørn J   Nohr Ellen Aagaard EA  

PloS one 20150910 9


<h4>Background</h4>In studies of perfluoroalkyl acids, the validity and comparability of measured concentrations may be affected by differences in the handling of biospecimens. We aimed to investigate whether measured plasma levels of perfluoroalkyl acids differed between blood samples subjected to delay and transportation prior to processing and samples with immediate processing and freezing.<h4>Methods</h4>Pregnant women recruited at Aarhus University Hospital, Denmark, (n = 88) provided paire  ...[more]

Similar Datasets

| S-EPMC7433207 | biostudies-literature
| PRJNA672734 | ENA
| PRJNA672733 | ENA
| S-EPMC5454506 | biostudies-literature
| S-EPMC7902524 | biostudies-literature
| S-EPMC6221990 | biostudies-literature
| S-EPMC4838759 | biostudies-literature
| S-EPMC4417395 | biostudies-literature
| S-EPMC7984356 | biostudies-literature
| S-EPMC8587818 | biostudies-literature