Unknown

Dataset Information

0

Development of a rapid Buffer-exchange system for time-resolved ATR-FTIR spectroscopy with the step-scan mode.


ABSTRACT: Attenuated total reflectance (ATR)-FTIR spectroscopy has been widely used to probe protein structural changes under various stimuli, such as light absorption, voltage change, and ligand binding, in aqueous conditions. Time-resolved measurements require a trigger, which can be controlled electronically; therefore, light and voltage changes are suitable. Here we developed a novel, rapid buffer-exchange system for time-resolved ATR-FTIR spectroscopy to monitor the ligand- or ion-binding re-action of a protein. By using the step-scan mode (time resolution; 2.5 ms), we confirmed the completion of the buffer-exchange reaction within ?25 ms; the process was monitored by the infrared absorption change of a nitrate band at 1,350 cm(-1). We also demonstrated the anion-binding reaction of a membrane protein, Natronomonas pharaonis halorhodopsin (pHR), which binds a chloride ion in the initial anion-binding site near the retinal chromophore. The formation of chloride- or nitrate-bound pHR was confirmed by an increase of the retinal absorption band at 1,528 cm(-1). It also should be noted that low sample consumption (?1 µg of protein) makes this new method a powerful technique to understand ligand-protein and ion-protein interactions, particularly for membrane proteins.

SUBMITTER: Furutani Y 

PROVIDER: S-EPMC4629687 | biostudies-literature | 2013

REPOSITORIES: biostudies-literature

altmetric image

Publications

Development of a rapid Buffer-exchange system for time-resolved ATR-FTIR spectroscopy with the step-scan mode.

Furutani Yuji Y   Kimura Tetsunari T   Okamoto Kido K  

Biophysics (Nagoya-shi, Japan) 20130810


Attenuated total reflectance (ATR)-FTIR spectroscopy has been widely used to probe protein structural changes under various stimuli, such as light absorption, voltage change, and ligand binding, in aqueous conditions. Time-resolved measurements require a trigger, which can be controlled electronically; therefore, light and voltage changes are suitable. Here we developed a novel, rapid buffer-exchange system for time-resolved ATR-FTIR spectroscopy to monitor the ligand- or ion-binding re-action o  ...[more]

Similar Datasets

| S-EPMC5985031 | biostudies-literature
| S-EPMC9295121 | biostudies-literature
| S-EPMC8315140 | biostudies-literature
| S-EPMC3972897 | biostudies-literature
| S-EPMC5085690 | biostudies-literature
| S-EPMC7248856 | biostudies-literature
| S-EPMC7195430 | biostudies-literature
| S-EPMC10839901 | biostudies-literature
| S-EPMC9404783 | biostudies-literature
| S-EPMC8740966 | biostudies-literature