Cell-free plasma hemoglobin removal by dialyzers with various permeability profiles.


ABSTRACT: The release of hemoglobin from mechanically stressed erythrocytes into plasma is a general side effect of extracorporeal therapies, such as extracorporeal membrane oxygenation or hemodialysis. In many reported cases dialysis patients showed elevated cell-free plasma hemoglobin (CPH) levels which are associated with pathophysiological effects. In this in vitro study, the CPH clearance capacity of various filters with different permeability profiles was measured. Simulated dialysis treatments were conducted and clearance was calculated from variations in CPH concentrations over time by measuring plasma absorbance at 405?nm. Conventional high-flux filters exhibited no detectable clearance of CPH. High-flux filters with extended permeability exhibited clearances between 5.8?±?1.2 and 12.7?±?1.7?ml/min when tested with plasma and between 5.8?±?1.2 and 11.3?±?1.6?ml/min when tested with whole blood. septeX high-cutoff filters had clearances between 13.8?±?1.8 and 15.5?±?1.7?ml/min when tested with plasma and of 22.6?±?2.9?ml/min when tested with whole blood. This study demonstrated that filters with extended permeability and the septeX filter enable CPH removal when used as in chronic and acute settings.

SUBMITTER: Hulko M 

PROVIDER: S-EPMC4639840 | biostudies-literature | 2015

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cell-free plasma hemoglobin removal by dialyzers with various permeability profiles.

Hulko Michael M   Kunz Melanie M   Yildirim Mehmet M   Homeyer Sandra S   Amon Oliver O   Krause Bernd B  

Scientific reports 20151110


The release of hemoglobin from mechanically stressed erythrocytes into plasma is a general side effect of extracorporeal therapies, such as extracorporeal membrane oxygenation or hemodialysis. In many reported cases dialysis patients showed elevated cell-free plasma hemoglobin (CPH) levels which are associated with pathophysiological effects. In this in vitro study, the CPH clearance capacity of various filters with different permeability profiles was measured. Simulated dialysis treatments were  ...[more]

Similar Datasets

| S-EPMC4251612 | biostudies-other
| S-EPMC6506348 | biostudies-literature
| S-EPMC8559716 | biostudies-literature
| S-EPMC5123289 | biostudies-literature
| S-EPMC6900719 | biostudies-literature
| S-EPMC5711346 | biostudies-literature
| S-EPMC6678393 | biostudies-literature
| S-EPMC9372268 | biostudies-literature
| S-EPMC2941010 | biostudies-literature
| S-EPMC4591759 | biostudies-literature