Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe.


ABSTRACT: We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of 8 ?m (in air). In posterior segment mode, the design has a lateral resolution of 9 ?m, 7.4 mm imaging depth range (in air), 4.9 mm 6dB fall-off range (in air), and peak sensitivity of 103 dB over a 22° field of view (FOV). In anterior segment mode, the design has a lateral resolution of 24 ?m, imaging depth range of 7.4 mm (in air), 6dB fall-off range of 4.5 mm (in air), depth-of-focus of 3.6 mm, and a peak sensitivity of 99 dB over a 17.5 mm FOV. In addition, the probe includes a wide-field iris imaging system to simplify alignment. A fold mirror assembly actuated by a bi-stable rotary solenoid was used to switch between anterior and posterior segment imaging modes, and a miniature motorized translation stage was used to adjust the objective lens position to correct for patient refraction between -12.6 and + 9.9 D. The entire probe weighs less than 630 g with a form factor of 20.3 x 9.5 x 8.8 cm. Healthy volunteers were imaged to illustrate imaging performance.

SUBMITTER: Nankivil D 

PROVIDER: S-EPMC4646558 | biostudies-literature | 2015 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe.

Nankivil Derek D   Waterman Gar G   LaRocca Francesco F   Keller Brenton B   Kuo Anthony N AN   Izatt Joseph A JA  

Biomedical optics express 20151021 11


We describe the first handheld, swept source optical coherence tomography (SSOCT) system capable of imaging both the anterior and posterior segments of the eye in rapid succession. A single 2D microelectromechanical systems (MEMS) scanner was utilized for both imaging modes, and the optical paths for each imaging mode were optimized for their respective application using a combination of commercial and custom optics. The system has a working distance of 26.1 mm and a measured axial resolution of  ...[more]

Similar Datasets

| S-EPMC4699182 | biostudies-literature
| S-EPMC6538171 | biostudies-literature
| S-EPMC5555612 | biostudies-literature
| S-EPMC5757396 | biostudies-literature
| S-EPMC8136703 | biostudies-literature
| S-EPMC10688841 | biostudies-literature
| S-EPMC8745779 | biostudies-literature
| S-EPMC7584205 | biostudies-literature
| S-EPMC9436129 | biostudies-literature
| S-EPMC8720848 | biostudies-literature