Ontology highlight
ABSTRACT: Background
Buttonhole cannulation (BHC) has been associated with a greater risk of arteriovenous fistula (AVF)-related infections and septicemia than the rope ladder cannulation (RLC) in in-center hemodialysis (HD). Such infections have never been studied in satellite HD units.Study design
Retrospective single center study.Setting and participant
All patients in our satellite HD unit using a native AVF from 1 January, 1990, to 31 December, 2012.Study period
Two different kinds of cannulation have been used during the study period: From 1 January, 1990 to 1, January, 1998 RLC was used in the unit (period 1). After 1 January, 1998 onwards, all the patients were switched within 3 months to BHC (period 2).Outcomes
Three different infectious events were observed during the two periods: local AVF infection, bacteremia, and combined infection. The aim of this study was to evaluate the incidence of AVF-related infections in our low-care HD unit and to determine whether BHC is associated with an increased risk of infection in this population.Results
162 patients were analyzed; 68 patients participated to period 1 and 115 to period 2. Sixteen infectious events occurred. Incidences of AVF-related infectious events were 0.05 [95% CI, 0.02-0.16] and 0.13/1000 AVF-days [95% CI, 0.0.8-0.23], for period 1 and 2 (p = 0.44) respectively. Recurrence of AVF-related infection was observed only during period 2. Unadjusted incidence rate ratio (IRR) of all infections was 0.39 (95%CI 0.12-1.37). Two complicated infections occurred during the study period: one in period 1 and one in period 2.Limitations
Observational retrospective single centre study.Conclusions
BHC is not associated with an increased infectious incidence in our HD population from a satellite dialysis unit. In the rare patients with AVF-related infection it seems necessary to change cannulation sites as recurrence of infection might be an event more frequent with BHC.
SUBMITTER: Bechade C
PROVIDER: S-EPMC4648583 | biostudies-literature | 2015
REPOSITORIES: biostudies-literature
PloS one 20151117 11
<h4>Background</h4>Buttonhole cannulation (BHC) has been associated with a greater risk of arteriovenous fistula (AVF)-related infections and septicemia than the rope ladder cannulation (RLC) in in-center hemodialysis (HD). Such infections have never been studied in satellite HD units.<h4>Study design</h4>Retrospective single center study.<h4>Setting and participant</h4>All patients in our satellite HD unit using a native AVF from 1 January, 1990, to 31 December, 2012.<h4>Study period</h4>Two di ...[more]