Full Field Digital Mammography (FFDM) versus CMOS Technology versus Tomosynthesis (DBT) - Which System Increases the Quality of Intraoperative Imaging?


ABSTRACT: Aim: The aim of this prospective clinical study was to assess whether it would be possible to reduce the rate of re-excisions and improve the quality using CMOS technology or digital breast tomosynthesis (DBT) compared to a conventional FFDM system. Material and Methods: An invasive breast cancer (BI-RADS 5) was diagnosed in 200 patients in the period from 5/2011 to 1/2012. After histological verification, a breast-conserving therapy was performed with intraoperative imaging. Three different imaging systems were used: 1) Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1?mm, resolution 85?µm pixel pitch, 8?l/mm as the standard; 2) BioVision™ (Bioptics, Tucson, USA), flat panel photodiode array, tungsten source, focus 0.05, resolution 50?µm pixel pitch, 12?l/mm; 3) Tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1?mm, resolution 85?µm pixel pitch, 8?l/mm, range: 50°, 25 projections, scan time >?20?s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiograms were prospectively shown to 3 radiologists. Results: Out of a total of 200 patients with histologically confirmed breast cancer (BI-RADS 6) 156 patients required no further operative therapy (re-excision) after breast-conserving therapy. A retrospective analysis (n?=?44) showed an increase in sensitivity with tomosynthesis compared to the BioVision™ (CMOS technology) and the Inspiration™ at a magnification of 1.0?:?1.0 of 8?% (p?Conclusions: The sensitivity of tomosynthesis for intraoperative radiography is significantly (p?

SUBMITTER: Schulz-Wendtland R 

PROVIDER: S-EPMC4651156 | biostudies-literature | 2012 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Full Field Digital Mammography (FFDM) versus CMOS Technology versus Tomosynthesis (DBT) - Which System Increases the Quality of Intraoperative Imaging?

Schulz-Wendtland R R   Dilbat G G   Bani M M   Fasching P A PA   Lux M P MP   Wenkel E E   Schwab S S   Loehberg C R CR   Jud S M SM   Rauh C C   Bayer C M CM   Beckmann M W MW   Uder M M   Meier-Meitinger M M  

Geburtshilfe und Frauenheilkunde 20120601 6


<b>Aim:</b> The aim of this prospective clinical study was to assess whether it would be possible to reduce the rate of re-excisions and improve the quality using CMOS technology or digital breast tomosynthesis (DBT) compared to a conventional FFDM system. <b>Material and Methods:</b> An invasive breast cancer (BI-RADS 5) was diagnosed in 200 patients in the period from 5/2011 to 1/2012. After histological verification, a breast-conserving therapy was performed with intraoperative imaging. Three  ...[more]

Similar Datasets

| S-EPMC3864442 | biostudies-literature
| S-EPMC5961594 | biostudies-literature
| S-EPMC6324392 | biostudies-literature
| S-EPMC6317146 | biostudies-literature
| S-EPMC7781455 | biostudies-literature
| S-EPMC3830430 | biostudies-other
| S-EPMC6493215 | biostudies-literature
| S-EPMC2809723 | biostudies-other
| S-EPMC7706877 | biostudies-literature
| S-EPMC9975365 | biostudies-literature