Unknown

Dataset Information

0

Preparation of intravenous cholesterol tracer using current good manufacturing practices.


ABSTRACT: Studies of human reverse cholesterol transport require intravenous infusion of cholesterol tracers. Because insoluble lipids may pose risk and because it is desirable to have consistent doses of defined composition available over many months, we investigated the manufacture of cholesterol tracer under current good manufacturing practice (CGMP) conditions appropriate for phase 1 investigation. Cholesterol tracer was prepared by sterile admixture of unlabeled cholesterol or cholesterol-d7 in ethanol with 20% Intralipid(®). The resulting material was filtered through a 1.2 micron particulate filter, stored at 4°C, and tested at time 0, 1.5, 3, 6, and 9 months for sterility, pyrogenicity, autoxidation, and particle size and aggregation. The limiting factor for stability was a rise in thiobarbituric acid-reacting substances of 9.6-fold over 9 months (P < 0.01). The emulsion was stable with the Z-average intensity-weighted mean droplet diameter remaining at 60 nm over 23 months. The zeta potential (a measure of negative surface charge protecting from aggregation) was unchanged at -36.2. Rapid cholesterol pool size was 25.3 ± 1.3 g. Intravenous cholesterol tracer was stable at 4°C for 9 months postproduction. CGMP manufacturing methods can be achieved in the academic setting and need to be considered for critical components of future metabolic studies.

SUBMITTER: Lin X 

PROVIDER: S-EPMC4655978 | biostudies-literature | 2015 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Preparation of intravenous cholesterol tracer using current good manufacturing practices.

Lin Xiaobo X   Ma Lina L   Racette Susan B SB   Swaney William P WP   Ostlund Richard E RE  

Journal of lipid research 20150928 12


Studies of human reverse cholesterol transport require intravenous infusion of cholesterol tracers. Because insoluble lipids may pose risk and because it is desirable to have consistent doses of defined composition available over many months, we investigated the manufacture of cholesterol tracer under current good manufacturing practice (CGMP) conditions appropriate for phase 1 investigation. Cholesterol tracer was prepared by sterile admixture of unlabeled cholesterol or cholesterol-d7 in ethan  ...[more]

Similar Datasets

| S-EPMC10022648 | biostudies-literature
| S-EPMC7347214 | biostudies-literature
| S-EPMC5352535 | biostudies-literature
| S-EPMC9666930 | biostudies-literature
| S-EPMC7076491 | biostudies-literature
| S-EPMC3073073 | biostudies-literature
| S-EPMC7739696 | biostudies-literature
| S-EPMC5862873 | biostudies-literature
| S-EPMC6344902 | biostudies-other
| S-EPMC5788871 | biostudies-other