Unknown

Dataset Information

0

Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.


ABSTRACT: Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation.Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB orifice was then analyzed in 88 patients with bifurcation lesions treated with either Xience V (everolimus-eluting stent) or Resolute Integrity [zotarolimus-eluting stent (ZES)]. The SB orifice area (A) and the area obstructed by struts (B) were calculated, and the %open area was evaluated as (A-B)/A*100.Linear regression modeling demonstrated that the observed departures of the intercept and slope were not significantly different from 0 (-0.12 ± 0.22, P=0.59) and 1 (1.01 ± 0.06, R(2)=0.88, P=0.87), respectively. In cases without SB dilatation, the %open area was significantly larger in the everolimus-eluting stent group (n=25) than in the ZES group [n=32; 89.2% (83.7-91.3) vs. 84.3% (78.9-87.8), P=0.04]. A significant difference in %open area between cases with and those without SB dilatation was demonstrated in the ZES group [91.4% (86.1-94.0) vs. 84.3% (78.9-87.8), P=0.04].The accuracy of SB orifice measurement on an en-face OCT image was validated using a phantom model. This novel approach enables quantitative evaluation of the differences in SB orifice area free from struts among different stent types and different treatment strategies in vivo.

SUBMITTER: Minami Y 

PROVIDER: S-EPMC4679565 | biostudies-literature | 2016 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

Minami Yoshiyasu Y   Wang Zhao Z   Aguirre Aaron D AD   Lee Stephen S   Uemura Shiro S   Soeda Tsunenari T   Vergallo Rocco R   Raffel Owen C OC   Barlis Peter P   Itoh Tomonori T   Lee Hang H   Fujimoto James J   Jang Ik-Kyung IK  

Coronary artery disease 20160101 1


<h4>Objective</h4>Methods for intravascular assessment of the side-branch (SB) orifice after stenting are not readily available. The aim of this study was to assess the utility of an en-face projection processing for optical coherence tomography (OCT) images for SB evaluation.<h4>Methods</h4>Measurements of the SB orifice obtained using en-face OCT images were validated using a phantom model. Linear regression modeling was applied to estimated area measurements made on the en-face images. The SB  ...[more]

Similar Datasets

| S-EPMC4574687 | biostudies-other
| S-EPMC6999681 | biostudies-literature
| S-EPMC5552220 | biostudies-literature
| S-EPMC6602142 | biostudies-literature
| S-EPMC8363606 | biostudies-literature
| S-EPMC8525711 | biostudies-literature
| S-EPMC7320001 | biostudies-literature
| S-EPMC8307697 | biostudies-literature
| S-EPMC7965437 | biostudies-literature
| S-EPMC8248257 | biostudies-literature