Unknown

Dataset Information

0

Gradient-induced voltages on 12-lead ECGs during high duty-cycle MRI sequences and a method for their removal considering linear and concomitant gradient terms.


ABSTRACT: To restore 12-lead electrocardiographic (ECG) signal fidelity inside MRI by removing magnetic field gradient-induced voltages during high gradient duty cycle sequences.A theoretical equation was derived to provide first- and second-order electrical fields induced at individual ECG electrodes as a function of gradient fields. Experiments were performed at 3T on healthy volunteers using a customized acquisition system that captured the full amplitude and frequency response of ECGs, or a commercial recording system. The 19 equation coefficients were derived via linear regression of data from accelerated sequences and were used to compute induced voltages in real-time during full resolution sequences to remove ECG artifacts. Restored traces were evaluated relative to ones acquired without imaging.Measured induced voltages were 0.7 V peak-to-peak during balanced steady state free precession (bSSFP) with the heart at the isocenter. Applying the equation during gradient echo sequencing, three-dimensional fast spin echo, and multislice bSSFP imaging restored nonsaturated traces and second-order concomitant terms showed larger contributions in electrodes further from the magnet isocenter. Equation coefficients are evaluated with high repeatability (??=?0.996) and are dependent on subject, sequence, and slice orientation.Close agreement between theoretical and measured gradient-induced voltages allowed for real-time removal. Prospective estimation of sequence periods in which large induced voltages occur may allow hardware removal of these signals.

SUBMITTER: Zhang SH 

PROVIDER: S-EPMC4689682 | biostudies-literature | 2016 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Gradient-induced voltages on 12-lead ECGs during high duty-cycle MRI sequences and a method for their removal considering linear and concomitant gradient terms.

Zhang Shelley HuaLei SH   Tse Zion Tsz Ho ZT   Dumoulin Charles L CL   Kwong Raymond Y RY   Stevenson William G WG   Watkins Ronald R   Ward Jay J   Wang Wei W   Schmidt Ehud J EJ  

Magnetic resonance in medicine 20150623 5


<h4>Purpose</h4>To restore 12-lead electrocardiographic (ECG) signal fidelity inside MRI by removing magnetic field gradient-induced voltages during high gradient duty cycle sequences.<h4>Theory and methods</h4>A theoretical equation was derived to provide first- and second-order electrical fields induced at individual ECG electrodes as a function of gradient fields. Experiments were performed at 3T on healthy volunteers using a customized acquisition system that captured the full amplitude and  ...[more]

Similar Datasets

| S-EPMC7660886 | biostudies-literature
| S-EPMC8015789 | biostudies-literature
| S-EPMC3623879 | biostudies-literature
| S-EPMC5266676 | biostudies-literature
| S-EPMC6635636 | biostudies-literature
| S-EPMC6289642 | biostudies-literature
| S-EPMC4507601 | biostudies-literature
| S-EPMC2762498 | biostudies-other
| S-EPMC5740018 | biostudies-literature
| S-EPMC4055293 | biostudies-literature