Cardiovascular magnetic resonance imaging of myocardial oedema following acute myocardial infarction: Is whole heart coverage necessary?


ABSTRACT: AAR measurement is useful when assessing the efficacy of reperfusion therapy and novel cardioprotective agents after myocardial infarction. Multi-slice (Typically 10-12) T2-STIR has been used widely for its measurement, typically with a short axis stack (SAX) covering the entire left ventricle, which can result in long acquisition times and multiple breath holds. This study sought to compare 3-slice T2-short-tau inversion recovery (T2- STIR) technique against conventional multi-slice T2-STIR technique for the assessment of area at risk (AAR).CMR imaging was performed on 167 patients after successful primary percutaneous coronary intervention. 82 patients underwent a novel 3-slice SAX protocol and 85 patients underwent standard 10-slice SAX protocol. AAR was obtained by manual endocardial and epicardial contour mapping followed by a semi- automated selection of normal myocardium; the volume was expressed as mass (%) by two independent observers.85 patients underwent both 10-slice and 3-slice imaging assessment showing a significant and strong correlation (intraclass correlation coefficient?=?0.92;p?

SUBMITTER: Hamshere S 

PROVIDER: S-EPMC4724400 | biostudies-literature | 2016 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cardiovascular magnetic resonance imaging of myocardial oedema following acute myocardial infarction: Is whole heart coverage necessary?

Hamshere Stephen S   Jones Daniel A DA   Pellaton Cyril C   Longchamp Danielle D   Burchell Tom T   Mohiddin Saidi S   Moon James C JC   Kastrup Jens J   Locca Didier D   Petersen Steffen E SE   Westwood Mark M   Mathur Anthony A  

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance 20160123


<h4>Background</h4>AAR measurement is useful when assessing the efficacy of reperfusion therapy and novel cardioprotective agents after myocardial infarction. Multi-slice (Typically 10-12) T2-STIR has been used widely for its measurement, typically with a short axis stack (SAX) covering the entire left ventricle, which can result in long acquisition times and multiple breath holds. This study sought to compare 3-slice T2-short-tau inversion recovery (T2- STIR) technique against conventional mult  ...[more]

Similar Datasets

| S-EPMC10099819 | biostudies-literature
| S-EPMC11347049 | biostudies-literature
| S-EPMC1768817 | biostudies-literature
| S-EPMC9425200 | biostudies-literature
| S-EPMC2809051 | biostudies-literature
| S-EPMC5219670 | biostudies-literature
| S-EPMC8924205 | biostudies-literature
| S-EPMC4650341 | biostudies-literature
| S-EPMC6117925 | biostudies-literature