Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up?


ABSTRACT:

Purpose

To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.

Methods

Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculated and coefficients of variation were used for comparisons.

Results

Measurement variability for the longest and average diameter of SSNs was ±1.3 mm (±13.0%) and ±1.3 mm (±14.4%) in situation 1, and ±2.2 mm (±21.0%) and ±2.1 mm (±21.3%) in situation 2, respectively. For solid portion, measurement variability on lung and mediastinal windows was ±1.2 mm (±27.1%) and ±0.8 mm (±24.0%) in situation 1, and ±3.7 mm (±61.0%) and ±1.5 mm (±47.3%) in situation 2, respectively. There were no significant differences in the degree of variability between the longest and average diameters and between the lung and mediastinal window settings (p>0.05). However, measurement variability significantly increased when the follow-up and initial CT readers were different (p<0.001).

Conclusions

A cutoff of ±2.2 mm can be reliably used to determine true nodule growth on follow-up CT. Solid portion measurements were not reliable in evaluating SSNs' change when readers of initial and follow-up CT were different.

SUBMITTER: Kim H 

PROVIDER: S-EPMC4747473 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement Variability of Persistent Pulmonary Subsolid Nodules on Same-Day Repeat CT: What Is the Threshold to Determine True Nodule Growth during Follow-Up?

Kim Hyungjin H   Park Chang Min CM   Song Yong Sub YS   Sunwoo Leonard L   Choi Ye Ra YR   Kim Jung Im JI   Kim Jae Hyun JH   Bae Jae Seok JS   Lee Jong Hyuk JH   Goo Jin Mo JM  

PloS one 20160209 2


<h4>Purpose</h4>To assess the measurement variability of subsolid nodules (SSNs) in follow-up situations and to compare the degree of variability between measurement metrics.<h4>Methods</h4>Two same-day repeat-CT scans of 69 patients (24 men and 45 women) with 69 SSNs were randomly assigned as initial or follow-up scans and were read by the same (situation 1) or different readers (situation 2). SSN size and solid portion size were measured in both situations. Measurement variability was calculat  ...[more]

Similar Datasets

| S-EPMC5810988 | biostudies-literature
| S-EPMC9929384 | biostudies-literature
| S-EPMC10629176 | biostudies-literature
| S-EPMC8182721 | biostudies-literature
| S-EPMC6790827 | biostudies-literature
| S-EPMC6823608 | biostudies-literature
| S-EPMC8022255 | biostudies-literature
| S-EPMC8200192 | biostudies-literature
| S-EPMC5766558 | biostudies-other
| S-EPMC6426580 | biostudies-literature