Unknown

Dataset Information

0

Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects.


ABSTRACT: Deficient retro-aortic rim has been identified as a risk factor for device erosion following trans-catheter closure of atrial septal defects (ASDs). Transthoracic echocardiography (TTE) is the primary screening method for subjects for possible device closure of ASD, but its reliability in measuring retro-aortic rim size has not been assessed previously.A single-institution cross-sectional analysis of children and adults referred for trans-catheter device closure of single ostium secundum ASD from January 1, 2005 to April 1, 2012 with reviewable TTE and trans-esophageal echocardiogram images was performed. Inter-rater reliability of measurements was tested in a 24% sample. Accuracy of TTE measurement of retro-aortic rim was assessed using a Bland-Altman plot with trans-esophageal echocardiogram measurement as the gold standard. Test characteristics of TTE detection of deficient retro-aortic rim were calculated. Risk factors for misclassification of deficient retro-aortic rim were assessed using receiver operator characteristic curves. Risk factors for measurement error were assessed through multivariate linear regression.In total, 163 subjects of median age 5 years (range: 0.3-46 years) were included. Trans-thoracic echocardiography had 90% sensitivity, 84% specificity, 90% positive predictive value, and 83% negative predictive value to detect deficient retro-aortic rim. Bland-Altman plot demonstrated no fixed bias (P?=?.23), but errors in measurement increased on average as the aortic rim increased in size (P?

SUBMITTER: O'Byrne ML 

PROVIDER: S-EPMC4748720 | biostudies-literature | 2015 Jul-Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of Transthoracic Echocardiography in Assessing Retro-aortic Rim prior to Device Closure of Atrial Septal Defects.

O'Byrne Michael L ML   Glatz Andrew C AC   Goldberg David J DJ   Shinohara Russell R   Dori Yoav Y   Rome Jonathan J JJ   Gillespie Matthew J MJ  

Congenital heart disease 20140916 4


<h4>Objective</h4>Deficient retro-aortic rim has been identified as a risk factor for device erosion following trans-catheter closure of atrial septal defects (ASDs). Transthoracic echocardiography (TTE) is the primary screening method for subjects for possible device closure of ASD, but its reliability in measuring retro-aortic rim size has not been assessed previously.<h4>Design</h4>A single-institution cross-sectional analysis of children and adults referred for trans-catheter device closure  ...[more]

Similar Datasets

| S-EPMC4167195 | biostudies-literature
| S-EPMC7552712 | biostudies-literature
| S-EPMC5115996 | biostudies-literature
| S-EPMC5610181 | biostudies-literature
| S-EPMC2938468 | biostudies-literature
| S-EPMC7063168 | biostudies-literature
| S-EPMC7178077 | biostudies-literature
| S-EPMC10239810 | biostudies-literature
| S-EPMC7249310 | biostudies-literature
| S-EPMC7004670 | biostudies-literature