Unknown

Dataset Information

0

Efficacy of covered and bare stent in TIPS for cirrhotic portal hypertension: A single-center randomized trial.


ABSTRACT: We conducted a single-center randomized trial to compare the efficacy of 8 mm Fluency covered stent and bare stent in transjugular intrahepatic portosystemic shunt (TIPS) for cirrhotic portal hypertension. From January 2006 to December 2010, the covered (experimental group) or bare stent (control group) was used in 131 and 127 patients, respectively. The recurrence rates of gastrointestinal bleeding (18.3% vs. 33.9%, P = 0.004) and refractory hydrothorax/ascites (6.9% vs. 16.5%, P = 0.019) in the experimental group were significantly lower than those in the control group. The cumulative restenosis rates in 1, 2, 3, 4, and 5-years in the experimental group (6.9%, 11.5%, 19.1%, 26.0%, and 35.9%, respectively) were significantly lower (P < 0.001) than those in the control group (27.6%, 37.0%, 49.6%, 59.8%, 74.8%, respectively). Importantly, the 4 and 5-year survival rates in the experimental group (83.2% and 76.3%, respectively) were significantly higher (P = 0.001 and 0.02) than those in the control group (71.7% and 62.2%, respectively). The rate of secondary interventional therapy in the experimental group was significantly lower than that in the control group (20.6% vs. 49.6%; P < 0.001). Therefore, Fluency covered stent has advantages over the bare stent in terms of reducing the restenosis, recurrence, and secondary interventional therapy, whereas improving the long-term survival for post-TIPS patients.

SUBMITTER: Wang L 

PROVIDER: S-EPMC4753460 | biostudies-literature | 2016 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Efficacy of covered and bare stent in TIPS for cirrhotic portal hypertension: A single-center randomized trial.

Wang Lei L   Xiao Zhibo Z   Yue Zhendong Z   Zhao Hongwei H   Fan Zhenhua Z   Zhao Mengfei M   He Fuliang F   Dai Shan S   Qiu Bin B   Yao Jiannan J   Lin Qiushi Q   Dong Xiaoqun X   Liu Fuquan F  

Scientific reports 20160215


We conducted a single-center randomized trial to compare the efficacy of 8 mm Fluency covered stent and bare stent in transjugular intrahepatic portosystemic shunt (TIPS) for cirrhotic portal hypertension. From January 2006 to December 2010, the covered (experimental group) or bare stent (control group) was used in 131 and 127 patients, respectively. The recurrence rates of gastrointestinal bleeding (18.3% vs. 33.9%, P = 0.004) and refractory hydrothorax/ascites (6.9% vs. 16.5%, P = 0.019) in th  ...[more]

Similar Datasets

| S-EPMC4047332 | biostudies-literature
| S-EPMC4585958 | biostudies-literature
| S-EPMC8386873 | biostudies-literature
| S-EPMC7583235 | biostudies-literature
| S-EPMC9253474 | biostudies-literature
| S-EPMC8270758 | biostudies-literature
| S-EPMC8198761 | biostudies-literature
| S-EPMC7645189 | biostudies-literature
| S-EPMC7503357 | biostudies-literature
| S-EPMC7841802 | biostudies-literature