Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay.


ABSTRACT: The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 10(4) CFU mL(-1) or 10(5) CFU mL(-1) for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R(2)) of 0.916-0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (? 80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water.

SUBMITTER: Zhao Y 

PROVIDER: S-EPMC4756364 | biostudies-literature | 2016 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay.

Zhao Yong Y   Wang Haoran H   Zhang Pingping P   Sun Chongyun C   Wang Xiaochen X   Wang Xinrui X   Yang Ruifu R   Wang Chengbin C   Zhou Lei L  

Scientific reports 20160217


The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 10(4) CFU mL(-1) or 10(  ...[more]

Similar Datasets

| S-EPMC5050493 | biostudies-literature
| S-EPMC4660431 | biostudies-other
| S-EPMC11234362 | biostudies-literature
| S-EPMC5491072 | biostudies-literature
| S-EPMC7143093 | biostudies-literature
| S-EPMC8051755 | biostudies-literature
| S-EPMC5664425 | biostudies-literature
| S-EPMC6389906 | biostudies-literature
| PRJNA876122 | ENA
| S-EPMC8456594 | biostudies-literature