Comparison of the Performance of Cartomizer Style Electronic Cigarettes from Major Tobacco and Independent Manufacturers.


ABSTRACT:

Objective

This study compared the performance of 12 brands of cartomizer style electronic cigarettes (EC) using different puffing protocols and measured the concentrations of nicotine in each product.

Methods

Air flow rate, pressure drop, and aerosol absorbance were measured using two different protocols, first 10 puffs and a modified smoke-out protocol.

Results

First 10 puff protocol: The air flow rate required to produce aerosol ranged between brands from 4-21 mL/s. Pressure drop was relatively stable within a brand but ranged between brands from 14-71 mmH2O and was much lower than the earlier classic 3-piece models. Absorbance, a measure of aerosol density, was relatively consistent between puffs, but varied between brands. With the modified smoke-out protocol, mos

SUBMITTER: Williams M 

PROVIDER: S-EPMC4758646 | biostudies-literature | 2016