FEA model analysis of the effects of the stress distribution of saddle-type implants on the alveolar bone and the structural/physical stability of implants.


ABSTRACT: As dental implants receive masticatory stress, the distribution of stress is very important to peri-implant bone homeostasis and implant survival. In this report, we created a saddle-type implant and analyzed its stability and ability to distribute stress to the surrounding bone.The implants were designed as a saddle-type implant (SI) that wrapped around the alveolar bone, and the sizes of the saddles were 2.5, 3.5, 4.5, and 5.5 mm. The X and Y displacement were compared to clarify the effects of the saddle structures. The control group consisted of dental implants without the saddle design (CI). Using finite element modeling (FEM), the stress distribution around the dental implants was analyzed.With saddle-type implants, saddles longer than 4.5 mm were more effective for stress distribution than CI. Regarding lateral displacement, a SI of 2.5 mm was effective for stress distribution compared to lateral displacement. ASI that was 5.6 mm in length was more effective for stress distribution than a CI that was 10 mm in length.The saddle-type implant could have a bone-gaining effect. Because it has stress-distributing effects, it might protect the newly formed bone under the implant.

SUBMITTER: Kong YS 

PROVIDER: S-EPMC4761364 | biostudies-literature | 2016 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

FEA model analysis of the effects of the stress distribution of saddle-type implants on the alveolar bone and the structural/physical stability of implants.

Kong Yoon Soo YS   Park Jun Woo JW   Choi Dong Ju DJ  

Maxillofacial plastic and reconstructive surgery 20160220 1


<h4>Background</h4>As dental implants receive masticatory stress, the distribution of stress is very important to peri-implant bone homeostasis and implant survival. In this report, we created a saddle-type implant and analyzed its stability and ability to distribute stress to the surrounding bone.<h4>Methods</h4>The implants were designed as a saddle-type implant (SI) that wrapped around the alveolar bone, and the sizes of the saddles were 2.5, 3.5, 4.5, and 5.5 mm. The X and Y displacement wer  ...[more]

Similar Datasets

| S-EPMC6921117 | biostudies-literature
| S-EPMC5512929 | biostudies-other
| S-EPMC7279478 | biostudies-literature
2022-11-21 | PXD037422 | Pride
| S-EPMC7464638 | biostudies-literature
| S-EPMC5527078 | biostudies-literature
| S-EPMC3790282 | biostudies-literature
| S-EPMC3075106 | biostudies-literature
| S-EPMC7116284 | biostudies-literature
| S-EPMC7178163 | biostudies-literature