A highly sensitive monoclonal antibody based biosensor for quantifying 3-5 ring polycyclic aromatic hydrocarbons (PAHs) in aqueous environmental samples.


ABSTRACT: Immunoassays based on monoclonal antibodies (mAbs) are highly sensitive for the detection of polycyclic aromatic hydrocarbons (PAHs) and can be employed to determine concentrations in near real-time. A sensitive generic mAb against PAHs, named as 2G8, was developed by a three-step screening procedure. It exhibited nearly uniformly high sensitivity against 3-ring to 5-ring unsubstituted PAHs and their common environmental methylated PAHs, with IC50 values between 1.68-31 ?g/L (ppb). 2G8 has been successfully applied on the KinExA Inline Biosensor system for quantifying 3-5 ring PAHs in aqueous environmental samples. PAHs were detected at a concentration as low as 0.2 ?g/L. Furthermore, the analyses only required 10 min for each sample. To evaluate the accuracy of the 2G8-based biosensor, the total PAH concentrations in a series of environmental samples analyzed by biosensor and GC-MS were compared. In most cases, the results yielded a good correlation between methods. This indicates that generic antibody 2G8 based biosensor possesses significant promise for a low cost, rapid method for PAH determination in aqueous samples.

SUBMITTER: Li X 

PROVIDER: S-EPMC4767017 | biostudies-literature | 2016 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

A highly sensitive monoclonal antibody based biosensor for quantifying 3-5 ring polycyclic aromatic hydrocarbons (PAHs) in aqueous environmental samples.

Li Xin X   Kaattari Stephen L SL   Vogelbein Mary A MA   Vadas George G GG   Unger Michael A MA  

Sensing and Bio-Sensing Research 20160301


Immunoassays based on monoclonal antibodies (mAbs) are highly sensitive for the detection of polycyclic aromatic hydrocarbons (PAHs) and can be employed to determine concentrations in near real-time. A sensitive generic mAb against PAHs, named as 2G8, was developed by a three-step screening procedure. It exhibited nearly uniformly high sensitivity against 3-ring to 5-ring unsubstituted PAHs and their common environmental methylated PAHs, with IC<sub>50</sub> values between 1.68-31 μg/L (ppb). 2G  ...[more]

Similar Datasets

2012-04-18 | GSE37326 | GEO
2012-04-17 | E-GEOD-37326 | biostudies-arrayexpress
| S-EPMC6214506 | biostudies-literature
2017-01-01 | GSE87691 | GEO
| S-EPMC4255657 | biostudies-literature
| S-EPMC7136547 | biostudies-literature
| S-EPMC8844380 | biostudies-literature
| S-EPMC8003230 | biostudies-literature
| S-EPMC8025847 | biostudies-literature
| S-EPMC7769252 | biostudies-literature