0

High Rates of Occult Infection After Shoulder Fracture Fixation: Considerations for Conversion Shoulder Arthroplasty.


ABSTRACT:

Background

Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.

Questions/purposes

This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthroplasty for failed open reduction and internal fixation (ORIF) and the need for re-operation at 4.6-year follow-up.

Methods

Twenty-eight patients who underwent conversion to shoulder arthroplasty for any reason after fracture fixation were retrospectively reviewed in a single center. A pre-operative aspiration was done in 17 patients; all patients had intra-operative tissue sampling. All procedures were single-stage removal of hardware and performance of the arthroplasty. In cases of pre-operative positive bacterial growth, a single-stage procedure was performed according to the septic ENDO-Klinik protocol.

Results

In 4 of 17 pre-operative joint aspirations, bacterial growth was detected; one pre-operative negative aspiration demonstrated bacterial growth in intra-operative sampling. In three of them, the infection has been validated through intra-operatively results. Pre-operative aspiration showed a sensitivity of 75% and specificity of 92% (p?ConclusionsIn conclusion, the risk of low-grade shoulder infection after fracture osteosynthesis may be higher than in hip and knee joints, based on limited study data. Adequate pre-operative testing is recommended to rule out occult shoulder infection in this setting.

SUBMITTER: Klatte TO 

PROVIDER: S-EPMC4773694 | biostudies-literature | 2015 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

High Rates of Occult Infection After Shoulder Fracture Fixation: Considerations for Conversion Shoulder Arthroplasty.

Klatte Till O TO   Sabihi Reza R   Guenther Daniel D   Kamath Atul F AF   Rueger Johannes M JM   Gehrke Thorsten T   Kendoff Daniel D  

HSS journal : the musculoskeletal journal of Hospital for Special Surgery 20150617 3


<h4>Background</h4>Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.<h4>Questions/purposes</h4>This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthropla  ...[more]

Similar Datasets

| S-EPMC7516170 | biostudies-literature
| S-EPMC7029179 | biostudies-literature
| S-EPMC5481267 | biostudies-literature
| S-EPMC4252758 | biostudies-literature
| S-EPMC4233012 | biostudies-literature
| S-EPMC6555110 | biostudies-literature
| S-EPMC8695904 | biostudies-literature
| S-EPMC7413303 | biostudies-literature
| S-EPMC7505881 | biostudies-literature
| S-EPMC7910737 | biostudies-literature