Ontology highlight
ABSTRACT: Background
Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.Questions/purposes
This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthroplasty for failed open reduction and internal fixation (ORIF) and the need for re-operation at 4.6-year follow-up.Methods
Twenty-eight patients who underwent conversion to shoulder arthroplasty for any reason after fracture fixation were retrospectively reviewed in a single center. A pre-operative aspiration was done in 17 patients; all patients had intra-operative tissue sampling. All procedures were single-stage removal of hardware and performance of the arthroplasty. In cases of pre-operative positive bacterial growth, a single-stage procedure was performed according to the septic ENDO-Klinik protocol.Results
In 4 of 17 pre-operative joint aspirations, bacterial growth was detected; one pre-operative negative aspiration demonstrated bacterial growth in intra-operative sampling. In three of them, the infection has been validated through intra-operatively results. Pre-operative aspiration showed a sensitivity of 75% and specificity of 92% (p?ConclusionsIn conclusion, the risk of low-grade shoulder infection after fracture osteosynthesis may be higher than in hip and knee joints, based on limited study data. Adequate pre-operative testing is recommended to rule out occult shoulder infection in this setting.
SUBMITTER: Klatte TO
PROVIDER: S-EPMC4773694 | biostudies-literature | 2015 Oct
REPOSITORIES: biostudies-literature
Klatte Till O TO Sabihi Reza R Guenther Daniel D Kamath Atul F AF Rueger Johannes M JM Gehrke Thorsten T Kendoff Daniel D
HSS journal : the musculoskeletal journal of Hospital for Special Surgery 20150617 3
<h4>Background</h4>Existing hardware may contribute to increased risk of bacterial contamination and subsequent periprosthetic joint infection (PJI) in conversion shoulder arthroplasty performed for failed fracture fixation.<h4>Questions/purposes</h4>This study examined the incidence of positive pre-operative aspiration and inflammatory marker data, along with correlation of pre-operative positive aspiration or inflammatory markers and subsequent infection following conversion shoulder arthropla ...[more]