Unknown

Dataset Information

0

Ultra-precise detection of mutations by droplet-based amplification of circularized DNA.


ABSTRACT: NGS (next generation sequencing) has been widely used in studies of biological processes, ranging from microbial evolution to cancer genomics. However, the error rate of NGS (0.1 %?~?1 %) is still remaining a great challenge for comprehensively investigating the low frequency variations, and the current solution methods have suffered severe amplification bias or low efficiency.We creatively developed Droplet-CirSeq for relatively efficient, low-bias and ultra-sensitive identification of variations by combining millions of picoliter uniform-sized droplets with Cir-seq. Droplet-CirSeq is entitled with an incredibly low error rate of 3?~?5 X 10(-6). To systematically evaluate the performances of amplification uniformity and capability of mutation identification for Droplet-CirSeq, we took the mixtures of two E. coli strains as specific instances to simulate the circumstances of mutations with different frequencies. Compared with Cir-seq, the coefficient of variance of read depth for Droplet-CirSeq was 10 times less (p?=?2.6 X 10(-3)), and the identified allele frequency presented more concentrated to the authentic frequency of mixtures (p?=?4.8 X 10(-3)), illustrating a significant improvement of amplification bias and accuracy in allele frequency determination. Additionally, Droplet-CirSeq detected 2.5 times genuine SNPs (p??A, C-?>?T). Our findings indicated that 30 pg DNA input accommodated in 5?~?10 million droplets resulted in maximal detection of authentic mutations compared to 3 pg (p?=?1.2 X 10(-8)) and 300 pg input (p?=?2.2 X 10(-3)).We developed a method namely Droplet-CirSeq to significantly improve the amplification bias, which presents obvious superiority over the currently prevalent methods in exploitation of ultra-low frequency mutations. Droplet-CirSeq would be promisingly used in the identification of low frequency mutations initiated from extremely low input DNA, such as DNA of uncultured microorganisms, captured DNA of target region, circulation DNA of plasma et al, and its creative conception of rolling circle amplification in droplets would also be used in other low input DNA amplification fields.

SUBMITTER: Wang K 

PROVIDER: S-EPMC4784281 | biostudies-literature | 2016 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultra-precise detection of mutations by droplet-based amplification of circularized DNA.

Wang Kaile K   Ma Qin Q   Jiang Lan L   Lai Shujuan S   Lu Xuemei X   Hou Yali Y   Wu Chung-I CI   Ruan Jue J  

BMC genomics 20160309


<h4>Background</h4>NGS (next generation sequencing) has been widely used in studies of biological processes, ranging from microbial evolution to cancer genomics. However, the error rate of NGS (0.1 % ~ 1 %) is still remaining a great challenge for comprehensively investigating the low frequency variations, and the current solution methods have suffered severe amplification bias or low efficiency.<h4>Results</h4>We creatively developed Droplet-CirSeq for relatively efficient, low-bias and ultra-s  ...[more]

Similar Datasets

| S-EPMC3616050 | biostudies-literature
| S-EPMC3696383 | biostudies-literature
| S-EPMC384784 | biostudies-literature
| S-EPMC3936482 | biostudies-literature
2014-02-25 | E-GEOD-55327 | biostudies-arrayexpress
2024-04-24 | GSE186007 | GEO
| S-EPMC7063572 | biostudies-literature
| S-EPMC4945036 | biostudies-literature
| S-EPMC6251935 | biostudies-literature
| S-EPMC3437896 | biostudies-other