X-Ray Excited Luminescence Chemical Imaging of Bacterial Growth on Surfaces Implanted in Tissue.


ABSTRACT: A pH sensor film is developed that can be coated on an implant surface and imaged using a combination of X-ray excitation and visible spectroscopy to monitor bacterial infection and treatment of implanted medical devices (IMDs) through tissue. X-ray scintillators in the pH sensor film generate light when an X-ray beam irradiates them. This light first passes through a layer containing pH indicator that alters the spectrum according to pH, then passes through and out of the tissue where it is detected by a spectrometer. A reference region on the film is used to account for spectral distortion from wavelength-dependent absorption and scattering in the tissue. pH images are acquired by moving the sample relative to the X-ray beam and collecting a spectrum at each location, with a spatial resolution limited by the X-ray beam width. Using this X-ray excited luminescence chemical imaging (XELCI) to map pH through ex vivo porcine tissue, a pH drop is detected during normal bacterial growth on the sensor surface, and a restoration of the pH to the bulk value during antibiotic treatment over the course of hours with milli-meter resolution. Overall, XELCI provides a novel approach to noninvasively image surface pH for studying implant infections and treatments.

SUBMITTER: Wang F 

PROVIDER: S-EPMC4795460 | biostudies-literature | 2015 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

X-Ray Excited Luminescence Chemical Imaging of Bacterial Growth on Surfaces Implanted in Tissue.

Wang Fenglin F   Raval Yash Y   Tzeng Tzuen-Rong J TR   Anker Jeffrey N JN  

Advanced healthcare materials 20150121 6


A pH sensor film is developed that can be coated on an implant surface and imaged using a combination of X-ray excitation and visible spectroscopy to monitor bacterial infection and treatment of implanted medical devices (IMDs) through tissue. X-ray scintillators in the pH sensor film generate light when an X-ray beam irradiates them. This light first passes through a layer containing pH indicator that alters the spectrum according to pH, then passes through and out of the tissue where it is det  ...[more]

Similar Datasets

| S-EPMC3612352 | biostudies-literature
| S-EPMC5920648 | biostudies-literature
| S-EPMC8752854 | biostudies-literature
| S-EPMC8042637 | biostudies-literature
| S-EPMC6568243 | biostudies-literature
| S-EPMC9659724 | biostudies-literature
| S-EPMC6424530 | biostudies-literature
| S-EPMC9730498 | biostudies-literature
| S-EPMC6529414 | biostudies-literature
| S-EPMC3985768 | biostudies-literature