Data on comparison between FLEC and CLIMPAQ methods used for fast sorption measurements of VOCs on building materials.


ABSTRACT: A test emission chamber called CLIMPAQ has been coupled to a chromatography analyzer GC to measure volatile organic compounds (VOC) concentration during a sorption experiments (Fast sorption measurements of VOCs on building materials: Part 2 - Comparison between FLEC and CLIMPAQ methods, (Rizk et al., In press) [1]). The equations used to calculate the mass transfer coefficient and the thickness of the boundary layer developed on the surface of a material are presented. In addition, the experimental profiles obtained using the CLIMPAQ chamber is also presented in the presence and the absence of a building material. Finally, the impact of chamber size on the obtained concentration profile using different chambers is shown using 3 types of chambers having different volumes, 1 m(3), 30 m(3) and a micro chamber of 40 mL.

SUBMITTER: Rizk M 

PROVIDER: S-EPMC4796712 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5852263 | biostudies-literature
| S-EPMC3489090 | biostudies-other
| PRJEB28228 | ENA
| S-EPMC8493810 | biostudies-literature
| S-EPMC5462788 | biostudies-literature
| S-EPMC2830578 | biostudies-literature
| S-EPMC6660429 | biostudies-literature
| S-EPMC6240779 | biostudies-literature
| S-EPMC5754382 | biostudies-literature
| S-EPMC7275893 | biostudies-literature