Unknown

Dataset Information

0

Data indicating temperature response of Ti-6Al-4V thin-walled structure during its additive manufacture via Laser Engineered Net Shaping.


ABSTRACT: An OPTOMEC Laser Engineered Net Shaping (LENS(™)) 750 system was retrofitted with a melt pool pyrometer and in-chamber infrared (IR) camera for nondestructive thermal inspection of the blown-powder, direct laser deposition (DLD) process. Data indicative of temperature and heat transfer within the melt pool and heat affected zone atop a thin-walled structure of Ti-6Al-4V during its additive manufacture are provided. Melt pool temperature data were collected via the dual-wavelength pyrometer while the dynamic, bulk part temperature distribution was collected using the IR camera. Such data are provided in Comma Separated Values (CSV) file format, containing a 752×480 matrix and a 320×240 matrix of temperatures corresponding to individual pixels of the pyrometer and IR camera, respectively. The IR camera and pyrometer temperature data are provided in blackbody-calibrated, raw forms. Provided thermal data can aid in generating and refining process-property-performance relationships between laser manufacturing and its fabricated materials.

SUBMITTER: Marshall GJ 

PROVIDER: S-EPMC4802429 | biostudies-literature | 2016 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Data indicating temperature response of Ti-6Al-4V thin-walled structure during its additive manufacture via Laser Engineered Net Shaping.

Marshall Garrett J GJ   Thompson Scott M SM   Shamsaei Nima N  

Data in brief 20160309


An OPTOMEC Laser Engineered Net Shaping (LENS(™)) 750 system was retrofitted with a melt pool pyrometer and in-chamber infrared (IR) camera for nondestructive thermal inspection of the blown-powder, direct laser deposition (DLD) process. Data indicative of temperature and heat transfer within the melt pool and heat affected zone atop a thin-walled structure of Ti-6Al-4V during its additive manufacture are provided. Melt pool temperature data were collected via the dual-wavelength pyrometer while  ...[more]

Similar Datasets

| S-EPMC10641140 | biostudies-literature
| S-EPMC7435555 | biostudies-literature
| S-EPMC8125978 | biostudies-literature
| S-EPMC7215978 | biostudies-literature
| S-EPMC9901169 | biostudies-literature
| S-EPMC10854433 | biostudies-literature
| S-EPMC7560294 | biostudies-literature
| S-EPMC7291991 | biostudies-literature
| S-EPMC5455940 | biostudies-other
| S-EPMC6715245 | biostudies-literature