Robust Intensity Modulated Proton Therapy (IMPT) Increases Estimated Clinical Benefit in Head and Neck Cancer Patients.


ABSTRACT:

Purpose

To compare the clinical benefit of robust optimized Intensity Modulated Proton Therapy (minimax IMPT) with current photon Intensity Modulated Radiation Therapy (IMRT) and PTV-based IMPT for head and neck cancer (HNC) patients. The clinical benefit is quantified in terms of both Normal Tissue Complication Probability (NTCP) and target coverage in the case of setup and range errors.

Methods and materials

For 10 HNC patients, PTV-based IMRT (7 fields), minimax and PTV-based IMPT (2, 3, 4, 5 and 7 fields) plans were tested on robustness. Robust optimized plans differed from PTV-based plans in that they target the CTV and penalize possible error scenarios, instead of using the static isotropic CTV-PTV margin. Perturbed dose distributions of all plans were acquired by simulating in total 8060 setup (±3.5 mm) and range error (±3%) combinations. NTCP models for xerostomia and dysphagia were used to predict the clinical benefit of IMPT versus IMRT.

Results

The robustness criterion was met in the IMRT and minimax IMPT plans in all error scenarios, but this was only the case in 1 of 40 PTV-based IMPT plans. Seven (out of 10) patients had relatively large NTCP reductions in minimax IMPT plans compared to IMRT. For these patients, xerostomia and dysphagia NTCP values were reduced by 17.0% (95% CI; 13.0-21.1) and 8.1% (95% CI; 4.9-11.2) on average with minimax IMPT. Increasing the number of fields did not contribute to plan robustness, but improved organ sparing.

Conclusions

The estimated clinical benefit in terms of NTCP of robust optimized (minimax) IMPT is greater than that of IMRT and PTV-based IMPT in HNC patients. Furthermore, the target coverage of minimax IMPT plans in the presence of errors was comparable to IMRT plans.

SUBMITTER: van Dijk LV 

PROVIDER: S-EPMC4816406 | biostudies-literature | 2016

REPOSITORIES: biostudies-literature

altmetric image

Publications

Robust Intensity Modulated Proton Therapy (IMPT) Increases Estimated Clinical Benefit in Head and Neck Cancer Patients.

van Dijk Lisanne V LV   Steenbakkers Roel J H M RJ   ten Haken Bennie B   van der Laan Hans Paul HP   van 't Veld Aart A AA   Langendijk Johannes A JA   Korevaar Erik W EW  

PloS one 20160331 3


<h4>Purpose</h4>To compare the clinical benefit of robust optimized Intensity Modulated Proton Therapy (minimax IMPT) with current photon Intensity Modulated Radiation Therapy (IMRT) and PTV-based IMPT for head and neck cancer (HNC) patients. The clinical benefit is quantified in terms of both Normal Tissue Complication Probability (NTCP) and target coverage in the case of setup and range errors.<h4>Methods and materials</h4>For 10 HNC patients, PTV-based IMRT (7 fields), minimax and PTV-based I  ...[more]

Similar Datasets

| S-EPMC6615027 | biostudies-literature
| S-EPMC3651255 | biostudies-other
| S-EPMC8205952 | biostudies-literature
| S-EPMC8270077 | biostudies-literature
| S-EPMC3281975 | biostudies-other
| S-EPMC5474304 | biostudies-literature
| S-EPMC6871565 | biostudies-literature
| S-EPMC10341304 | biostudies-literature
| S-EPMC3174314 | biostudies-literature
| S-EPMC6493042 | biostudies-literature