Clinical problems of computer-guided implant surgery.


ABSTRACT: The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement.Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze differences of the implant fixture body between preoperative planned implant and postoperative placed implant, angular error and distance errors were evaluated.The mean angular errors between the preoperative planned and postoperative placed implant was 3.84°?±?1.49°; the mean distance errors between the planned and placed implants were 0.45?±?0.48 mm horizontally and 0.63?±?0.51 mm vertically at the implant neck and 0.70?±?0.63 mm horizontally and 0.64?±?0.57 mm vertically at the implant apex for all 19 implants.It is important to be able to utilize these methods in actual clinical settings by improving the various problems, including the considerations of patient mouth opening limitations, surgical guide preparation, and fixation.

SUBMITTER: Moon SY 

PROVIDER: S-EPMC4819455 | biostudies-literature | 2016 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Clinical problems of computer-guided implant surgery.

Moon Seong-Yong SY   Lee Kyoung-Rok KR   Kim Su-Gwan SG   Son Mee-Kyoung MK  

Maxillofacial plastic and reconstructive surgery 20160324 1


<h4>Background</h4>The utilization of a cone-beam computed tomography (CT)-assisted surgical template allows for predictable results because implant placement plans can be performed in the actual surgery. In order to assess the accuracy of the CT-guided surgery, angular errors and shoulder/apex distance errors were evaluated by data fusion from before and after the placement.<h4>Methods</h4>Computer-guided implant surgery was performed in five patients with 19 implants. In order to analyze diffe  ...[more]

Similar Datasets

| S-EPMC7502099 | biostudies-literature
| S-EPMC10439617 | biostudies-literature
| S-EPMC9314069 | biostudies-literature
| S-EPMC7064711 | biostudies-literature
| S-EPMC4305276 | biostudies-literature
| S-EPMC7231012 | biostudies-literature
| S-EPMC7141387 | biostudies-literature
| S-EPMC8802526 | biostudies-literature
| S-EPMC7246902 | biostudies-literature
| S-EPMC10455221 | biostudies-literature