Unknown

Dataset Information

0

Size-tunable copper nanocluster aggregates and their application in hydrogen sulfide sensing on paper-based devices.


ABSTRACT: Polystyrene sulfonate (PSS), a strong polyelectrolyte, was used to prepare red photoluminescent PSS-penicillamine (PA) copper (Cu) nanoclusters (NC) aggregates, which displayed high selectivity and sensitivity to the detection of hydrogen sulfide (H2S). The size of the PSS-PA-Cu NC aggregates could be readily controlled from 5.5??m to 173?nm using different concentrations of PSS, which enabled better dispersity and higher sensitivity towards H2S. PSS-PA-Cu NC aggregates provided rapid H2S detection by using the strong Cu-S interaction to quench NC photoluminescence as a sensing mechanism. As a result, a detection limit of 650?nM, which is lower than the maximum level permitted in drinking water by the World Health Organization, was achieved for the analysis of H2S in spring-water samples. Moreover, highly dispersed PSS-PA-Cu NC aggregates could be incorporated into a plate-format paper-based analytical device which enables ultra-low sample volumes (5??L) and feature shorter analysis times (30?min) compared to conventional solution-based methods. The advantages of low reagent consumption, rapid result readout, limited equipment, and long-term storage make this platform sensitive and simple enough to use without specialized training in resource constrained settings.

SUBMITTER: Chen PC 

PROVIDER: S-EPMC4845058 | biostudies-literature | 2016 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Size-tunable copper nanocluster aggregates and their application in hydrogen sulfide sensing on paper-based devices.

Chen Po-Cheng PC   Li Yu-Chi YC   Ma Jia-Yin JY   Huang Jia-Yu JY   Chen Chien-Fu CF   Chang Huan-Tsung HT  

Scientific reports 20160426


Polystyrene sulfonate (PSS), a strong polyelectrolyte, was used to prepare red photoluminescent PSS-penicillamine (PA) copper (Cu) nanoclusters (NC) aggregates, which displayed high selectivity and sensitivity to the detection of hydrogen sulfide (H2S). The size of the PSS-PA-Cu NC aggregates could be readily controlled from 5.5 μm to 173 nm using different concentrations of PSS, which enabled better dispersity and higher sensitivity towards H2S. PSS-PA-Cu NC aggregates provided rapid H2S detect  ...[more]

Similar Datasets

| S-EPMC3950207 | biostudies-literature
| S-EPMC5102667 | biostudies-literature
| S-EPMC3065124 | biostudies-literature
| S-EPMC5853728 | biostudies-literature
| S-EPMC6759990 | biostudies-literature
| S-EPMC9058623 | biostudies-literature
| S-EPMC6250125 | biostudies-literature
| S-EPMC8461779 | biostudies-literature
| S-EPMC4184000 | biostudies-literature
| S-EPMC4902284 | biostudies-literature